16. van Uden CJ, Besser MP. Test-retest reliability of temporal
and spatial gait characteristics measured with an instru-
mented walkway system (GAITRite). BMC Musculoskelet
Disord 2004; 5: 13.
17. Kuys SS, Brauer SG, Ada L. Test-retest reliability of the
GAITRite system in people with stroke undergoing reha-
bilitation. Disabil Rehabil 2011; 33: 1848–1853.
18. Cho KH, Lee HJ, Lee WH. Test-retest reliability of the
GAITRite walkway system for the spatiotemporal gait
parameters while dual-tasking in post-stroke patients.
Disabil Rehabil 2015; 37: 512–516.
19. Dolatabadi E, Taati B, Mihailidis A. Concurrent validity
of the Microsoft Kinect for Windows v2 for measuring
spatiotemporal gait parameters. Med Eng Phys 2016;
38: 952–958.
20. Castelli A, Paolini G, Cereatti A, Della Croce U. A 2D mar-
kerless gait analysis methodology: validation on healthy
subjects. Comput Math Methods Med 2015; 2015: 186780.
21. Eltoukhy M, Oh J, Kuenze C, Signorile J. Improved kinect-
based spatiotemporal and kinematic treadmill gait assess-
ment. Gait Posture 2017; 51: 77–83.
22. Geerse DJ, Coolen BH, Roerdink M. Kinematic validation
of a multi-Kinect v2 instrumented 10-meter walkway
for quantitative gait assessments. PLoS One 2015; 10:
e0139913.
23. Mentiplay BF, Perraton LG, Bower KJ, Pua Y, McGawa R,
Heywood S, et al. Gait assessment using the Microsoft
Xbox One Kinect: concurrent validity and inter-day relia-
bility of spatiotemporal and kinematic variables. J Biomech
2015; 48: 2166–2170.
24. Latorre J, Llorens R, Colomer C, Alcaniz M. Reliability
and comparison of Kinect-based methods for estimating
spatiotemporal gait parameters of healthy and post-stroke
individuals. J Biomech 2018; 72: 268–273.
25. Greene BR, Foran TG, McGrath D, Doheny EP, Burns A,
Caulfield B. A comparison of algorithms for body-worn sen-
sor-based spatiotemporal gait parameters to the GAITRite
electronic walkway. J Appl Biomech 2012; 28: 349–355.
26. Beauchet O, Herrmann FR, Grandjean R, Dubost V, Allali G.
Concurrent validity of SMTEC footswitches system for the
measurement of temporal gait parameters. Gait Posture
2008; 27: 156–159.
27. Bilney B, Morris M, Webster K. Concurrent related validity
of the GAITRite walkway system for quantification of the
spatial and temporal parameters of gait. Gait Posture
2003; 17: 68–74.
28. Hartmann A, Luzi S, Murer K, De Bie RA, De Bruin ED.
Concurrent validity of a trunk tri-axial accelerometer sys-
tem for gait analysis in older adults. Gait Posture 2009;
463
29: 444–448.
29. Washabaugh EP, Kalyanaraman T, Adamczyk PG, Claflin ES,
Krishnan C. Validity and repeatability of inertial measure-
ment units for measuring gait parameters. Gait Posture
2017; 55: 87–93.
30. Brahms CM, Zhao Y, Gerhard D, Barden JM. Stride length
determination during overground running using a single
foot-mounted inertial measurement unit. J Biomech 2018;
71: 302–305.
31. Zhang Z. A flexible new technique for camera calibration.
IEEE Trans Pattern Anal Mach Intell 2000; 22: 1330–1334.
32. Wang F, Stone E, Skubic M, Keller J, Abbott C, Rantz M.
Towards a passive low-cost in-home gait assessment
system for older adults. IEEE J Biomed Health Inform
2013; 17: 346–355.
33. Landis JR, Koch GG. The measurement of observer agre-
ement for categorical data. Biometrics 1977; 33: 159–174.
34. Giraudeau B, Mary JY. Planning a reproducibility study: how
many subjects and how many replicates per subject for
an expected width of the 95 per cent confidence interval
of the intraclass correlation coefficient. Stat Med 2001;
20: 3205–3214.
35. Wong JS, Jasani H, Poon V, Inness EL, McIlroy WE, Mans-
field A. Inter- and intra-rater reliability of the GAITRite
system among individuals with sub-acute stroke. Gait
Posture 2014; 40: 259–261.
36. Stokic DS, Horn TS, Ramshur JM, Chow JW. Agreement
between temporospatial gait parameters of an electronic
walkway and a motion capture system in healthy and
chronic stroke populations. Am J Phys Med Rehabil 2009;
88: 437–444.
37. Menz HB, Latt MD, Tiedemann A, Mun San Kwan M, Lord
SR. Reliability of the GAITRite walkway system for the
quantification of temporo-spatial parameters of gait in
young and older people. Gait Posture 2004; 20: 20–25.
38. Ross SA, Rice C, Von Behren K, Meyer A, Alexander R, Mur-
fin S. Reliability of sagittal plane hip, knee, and ankle joint
angles from a single frame of video data using the GAITRite
camera system. Physiother Theory Pract 2015; 31: 53–60.
39. Item-Glatthorn JF, Casartelli NC, Petrich-Munzinger J, Mun-
zinger UK, Maffiuletti NA. Validity of the intelligent device
for energy expenditure and activity accelerometry system
for quantitative gait analysis in patients with hip osteo-
arthritis. Arch Phys Med Rehabil 2012; 93: 2090–2093.
40. Hollman JH, Childs KB, McNeil ML, Mueller AC, Quilter CM,
Youdas JW. Number of strides required for reliable measu-
rements of pace, rhytm and variability parameters of gait
during normal and dual task walking in older individuals.
Gait Posture 2010; 32: 23–28.
Validity and reliability of a spatiotemporal gait-analysis system
J Rehabil Med 51, 2019