Journal of Rehabilitation Medicine 51-6 | Page 69

16. van Uden CJ, Besser MP. Test-retest reliability of temporal and spatial gait characteristics measured with an instru- mented walkway system (GAITRite). BMC Musculoskelet Disord 2004; 5: 13. 17. Kuys SS, Brauer SG, Ada L. Test-retest reliability of the GAITRite system in people with stroke undergoing reha- bilitation. Disabil Rehabil 2011; 33: 1848–1853. 18. Cho KH, Lee HJ, Lee WH. Test-retest reliability of the GAITRite walkway system for the spatiotemporal gait parameters while dual-tasking in post-stroke patients. Disabil Rehabil 2015; 37: 512–516. 19. Dolatabadi E, Taati B, Mihailidis A. Concurrent validity of the Microsoft Kinect for Windows v2 for measuring spatiotemporal gait parameters. Med Eng Phys 2016; 38: 952–958. 20. Castelli A, Paolini G, Cereatti A, Della Croce U. A 2D mar- kerless gait analysis methodology: validation on healthy subjects. Comput Math Methods Med 2015; 2015: 186780. 21. Eltoukhy M, Oh J, Kuenze C, Signorile J. Improved kinect- based spatiotemporal and kinematic treadmill gait assess- ment. Gait Posture 2017; 51: 77–83. 22. Geerse DJ, Coolen BH, Roerdink M. Kinematic validation of a multi-Kinect v2 instrumented 10-meter walkway for quantitative gait assessments. PLoS One 2015; 10: e0139913. 23. Mentiplay BF, Perraton LG, Bower KJ, Pua Y, McGawa R, Heywood S, et al. Gait assessment using the Microsoft Xbox One Kinect: concurrent validity and inter-day relia- bility of spatiotemporal and kinematic variables. J Biomech 2015; 48: 2166–2170. 24. Latorre J, Llorens R, Colomer C, Alcaniz M. Reliability and comparison of Kinect-based methods for estimating spatiotemporal gait parameters of healthy and post-stroke individuals. J Biomech 2018; 72: 268–273. 25. Greene BR, Foran TG, McGrath D, Doheny EP, Burns A, Caulfield B. A comparison of algorithms for body-worn sen- sor-based spatiotemporal gait parameters to the GAITRite electronic walkway. J Appl Biomech 2012; 28: 349–355. 26. Beauchet O, Herrmann FR, Grandjean R, Dubost V, Allali G. Concurrent validity of SMTEC footswitches system for the measurement of temporal gait parameters. Gait Posture 2008; 27: 156–159. 27. Bilney B, Morris M, Webster K. Concurrent related validity of the GAITRite walkway system for quantification of the spatial and temporal parameters of gait. Gait Posture 2003; 17: 68–74. 28. Hartmann A, Luzi S, Murer K, De Bie RA, De Bruin ED. Concurrent validity of a trunk tri-axial accelerometer sys- tem for gait analysis in older adults. Gait Posture 2009; 463 29: 444–448. 29. Washabaugh EP, Kalyanaraman T, Adamczyk PG, Claflin ES, Krishnan C. Validity and repeatability of inertial measure- ment units for measuring gait parameters. Gait Posture 2017; 55: 87–93. 30. Brahms CM, Zhao Y, Gerhard D, Barden JM. Stride length determination during overground running using a single foot-mounted inertial measurement unit. J Biomech 2018; 71: 302–305. 31. Zhang Z. A flexible new technique for camera calibration. IEEE Trans Pattern Anal Mach Intell 2000; 22: 1330–1334. 32. Wang F, Stone E, Skubic M, Keller J, Abbott C, Rantz M. Towards a passive low-cost in-home gait assessment system for older adults. IEEE J Biomed Health Inform 2013; 17: 346–355. 33. Landis JR, Koch GG. The measurement of observer agre- ement for categorical data. Biometrics 1977; 33: 159–174. 34. Giraudeau B, Mary JY. Planning a reproducibility study: how many subjects and how many replicates per subject for an expected width of the 95 per cent confidence interval of the intraclass correlation coefficient. Stat Med 2001; 20: 3205–3214. 35. Wong JS, Jasani H, Poon V, Inness EL, McIlroy WE, Mans- field A. Inter- and intra-rater reliability of the GAITRite system among individuals with sub-acute stroke. Gait Posture 2014; 40: 259–261. 36. Stokic DS, Horn TS, Ramshur JM, Chow JW. Agreement between temporospatial gait parameters of an electronic walkway and a motion capture system in healthy and chronic stroke populations. Am J Phys Med Rehabil 2009; 88: 437–444. 37. Menz HB, Latt MD, Tiedemann A, Mun San Kwan M, Lord SR. Reliability of the GAITRite walkway system for the quantification of temporo-spatial parameters of gait in young and older people. Gait Posture 2004; 20: 20–25. 38. Ross SA, Rice C, Von Behren K, Meyer A, Alexander R, Mur- fin S. Reliability of sagittal plane hip, knee, and ankle joint angles from a single frame of video data using the GAITRite camera system. Physiother Theory Pract 2015; 31: 53–60. 39. Item-Glatthorn JF, Casartelli NC, Petrich-Munzinger J, Mun- zinger UK, Maffiuletti NA. Validity of the intelligent device for energy expenditure and activity accelerometry system for quantitative gait analysis in patients with hip osteo- arthritis. Arch Phys Med Rehabil 2012; 93: 2090–2093. 40. Hollman JH, Childs KB, McNeil ML, Mueller AC, Quilter CM, Youdas JW. Number of strides required for reliable measu- rements of pace, rhytm and variability parameters of gait during normal and dual task walking in older individuals. Gait Posture 2010; 32: 23–28. Validity and reliability of a spatiotemporal gait-analysis system J Rehabil Med 51, 2019