258
J. Eur. Opt. Society-Rapid Publ. 22, 24( 2026)
the resulting cut after laser-induced optical breakdown, Photonics 11( 8), 685,( 2024). https:// doi. org / 10.3390 / photonics11080685.
31 Ryu S, et al., Optimizing plasma formation and minimizing microcavitation to enhance clinical outcomes in keratorefractive lenticule extraction, J. Refract. Surg. 41( 7), e635 – e644( 2025). https:// doi. org / 10.3928 / 1081597X-20250509-05.
32 Park ES et al., Reducing higher-order aberrations after keratorefractive lenticule extraction using asymmetric spacing spot / track distances with low-energy levels, J. Cataract Refract. Surg. 51( 10), 895 – 902( 2025). https:// doi. org / 10.1097 / j. jcrs. 0000000000001713.
33 Verma S, Hesser J, Arba-Mosquera S. Optimum laser beam characteristics for achieving smoother ablations in laser vision correction. Invest. Ophthalmol. Vis. Sci. 58( 4), 2021 – 2037( 2017). https:// doi. org / 10.1167 / iovs. 16-21025.
34 Bohač M, et al., Epithelial remodelling in myopia after keratorefractive lenticule extraction, Ophthalmol. Ther. 14( 6), 1237 – 1247( 2025). https:// doi. org / 10.1007 / s40123-025- 01138-7.
35 Gabric I, Pradhan KR, Arba-Mosquera S. Unique features of the ATOS laser for lenticule extraction: programming, intraoperative software use, and dissection techniques, in Femtosecond Laser Assisted Lenticule Extraction: Principles, Techniques, Complication Management, and Future Concepts in KLEx, edited by W. Sekundo, F. M. Wagner( Springer Nature Switzerland, Cham, 2024), pp. 339 – 347. https:// doi. org / 10.1007 / 978-3-031-60424-9 _ 24.
36 Pradhan K, Arba-Mosquera S, Lenticule and interface properties and geometries in SmartSight Ò, in Femtosecond Laser Assisted Lenticule Extraction: Principles, Techniques,
Complication Management, and Future Concepts in KLEx, edited by W. Sekundo, F. M. Wagner( Springer Nature Switzerland, Cham, 2024), pp. 329 – 338( 2024). https:// doi. org / 10.1007 / 978-3-031-60424-9 _ 23
37 Pradhan KR et al., Clinical results of SmartSight in four years experience, in Femtosecond Laser Assisted Lenticule Extraction: Principles, Techniques, Complication Management, and Future Concepts in KLEx, edited by W. Sekundo, F. M. Wagner( Springer Nature Switzerland, Cham, 2024), pp. 349 – 369. https:// doi. org / 10.1007 / 978-3-031-60424- 9 _ 25.
38 Taneri S, et al., Results of thin-cap small-incision lenticule extraction, J. Cataract Refract. Surg. 47( 4), 439 – 444( 2021). https:// doi. org / 10.1097 / j. jcrs. 0000000000000470.
39 Brar S, Ganesh S, Bhargav S. Comparison of intraoperative time taken for docking, lenticule dissection, and overall workflow for SMILE performed with the VisuMax 800 versus the VisuMax 500 femtosecond laser, J. Refract. Surg. 39( 9), 648( 2023). https:// doi. org / 10.3928 / 1081597X-20230726-03.
40 Li H, et al., Multi-focus non-periodic scanning method for femtosecond lasers based on DMD and galvanometer scanners [ Invited ], Chin. Opt. Lett. 22( 5), 051701( 2024). https:// doi. org / 10.1364 / COL. 22.051701.
41 Juhasz T, et al., Time-resolved observations of shock waves and cavitation bubbles generated by femtosecond laser pulses in corneal tissue and water, Lasers Surg. Med. 19( 1), 23 – 31( 1996). https:// doi. org / 10.1002 /( SICI) 1096-9101( 1996) 19: 1 % 3C23:: AID-LSM4 % 3E3.0. CO; 2-S.
42 Kehrer T, Arba-Mosquera S, A simple cornea deformation model, Adv. Opt. Technol. 10( 6), 433 – 450( 2021). https:// doi. org / 10.1515 / aot-2021-0039.