84
J. Eur. Opt. Society-Rapid Publ. 21, 39( 2025)
the use of a conventional imaging system, such as a lens, this method provides high resolution images of the object surface. Because of this, the FOV and the resolution can be adjusted without a change in the optics but by just changing the distances in the setup. This way, the setup is very versatile and easy to adapt for different measurement situations, which is especially convenient for process monitoring. Moreover, the shape of the GUWs can be captured without any additional demands on the sample, the frequency range or the type of excitation( i. e. continuous or pulsed). The only crucial requirement of stroboscopic coherent illumination is met by employing a pulse laser with a pulse length of 6 ns. Furthermore, with the measurement of the full wave field of the GUW, the technique allows to quantitatively determine the frequency and amplitude of the GUW. For this, we propose the evaluation of the structure function( SF) [ 19 ] for the measured height distributions, presenting a significant benefitinthefield of GUW detection. We compare our results with those obtained from asimulation.
2 Experimental setup and methods
2.1 Holographic measurements of GUW-induced surface deformation
By means of digital holography, the whole complex wave field, i. e. phase and amplitude, is measured by coding the phase into the interference pattern between an undistorted reference wave rð ~ xÞ and an object wave uð ~ xÞ scattered by the object. The intensity of the interference pattern is given by
I ð ~ xÞ ¼juð ~ xÞþrð ~ xÞj 2 ¼juð ~ xÞj 2 þjrð ~ xÞj 2 þ uð ~ xÞr ð ~ xÞþu ð ~ xÞrð ~ xÞ: ð1Þ
Several methods exist to separate the coherence function Cð ~ xÞ ¼uð ~ xÞr ð ~ xÞ from the intensity, with * denoting the complex conjugate. In our work, we make use of the so called spatial carrier method, introduced by Takeda et al. [ 20 ], which is based on tilting the reference wave, thereby modulating the object wave with a spatial carrier frequency. With the reference wave rð ~ xÞ known, this facilitates the determination of the full complex amplitude of the object wave by means of uð ~ xÞ ¼Cð ~ xÞrð ~ xÞ = jrð ~ xÞj 2.
The object wave is commonly recorded across a plane parallel to the object under inspection. Since the entire wave field is known, we employ propagation methods from scalar diffraction theory, such as the Fresnel propagation formula [ 21 ], to calculate the wave field across the object plane u O ð ~ x 0 Þ by
u O ð ~ x 0 Þ¼ i k z exp
�i 2 k z h exp �i k z j x ~ i 0 j 2! n h F �1 uð ~ xÞ exp �i p � k z j ~ io x~ 0 xj2 k z ð2Þ
where F �1 denotes the inverse Fourier transformation, z is the distance between the camera plane and the object plane and k is the wavelength of the light used for illuminating the sample.
The wave field in the object plane provides us with the image I ð x ~ 0
¼ju O ð x ~ 0 Þj 2 of the object. Since the propagation in equation( 2) is a purely numerical process, we do not need any additional imaging device, such as a lens objective.
Moreover, the phase distribution / ð x ~ 0 Þ¼argfu O ð x ~ 0 Þg
depends on the optical path between the light source and the camera and therefore also on the exact shape of the surface, with precision down to the single digit nanometer range. Guided ultrasonic waves can now be visualized by recording two different holograms: one with active piezoelectric excitation and one without any excitation. The phase difference / ð x ~ 0 Þ between the two measured object wave fields then yields the deformation, which is mainly caused by the GUW on the surface. Thereby, the wavelength and the amplitude of the GUW can be determined from the height distribution.
In order to measure the fast-travelling GUW, an INNOLAS SpitLight 600 pulsed laser was used with a pulse width of 6 ns to avoid motion artefacts. Thus, the pulse rate of max. 10 Hz constituted the limiting factor for the sample frequency. The experimental setup is shown in Figure 1. The mirror positioned at the edge of the object provides the reference wave, while the illuminated part of the object constitutes the object wave. Both wave fields then interfere and propagate towards the CMOS sensor, where the hologram is measured. For the measurement of the GUW, the sample plate was excited continuously with a piezo actuator attached on the back of the sample with a sine voltage wave with a defined frequency.
Large-scale defects in compound materials can lead to a change in the wavelength of the GUW due to a change of the effective thickness [ 3 ]. To demonstrate that our proposed method measures the correct wavelengths and thereby detects changes in the wavelength, we use two aluminum plates: sample 1 measuring 32.0 cm 9.4 cm 2.6 cm and sample 2 measuring 30.0 cm 11.7 cm 5.0 cm. For the excitation of GUWs, frequencies of f Exc = [ 60, 300 ] kHz in steps of 20 kHz were applied to the piezo actuator, with a peak-to-peak amplitude of 60 V p – p. The piezo actuator was a DuraAct patch from PI Ceramic GmbH with a length of 17 mm and a width of 13 mm. The thickness of the piezo actuator was 200 lm and its diameter was 10 mm.
2.2 Characterization of the out-of-plane displacement fields of the GUW with the structure function
By measuring the object wave field with digital holography, the phase of the light reflected from the surface is measured. Encoded in this phase distribution is the height of the object. For the characterization of the measured phase distributions, respectively the height distribution derived therefrom, the SF [ 19 ] can be used. The SF provides a statistical analysis of correlations on the surface by calculating finite differences and averaging these for all possible surface points. In the one-dimensional case, it is defined as
Ss ðÞ¼ 1 N � s
X N�s
i¼1 ðz i � z iþs Þ 2 ð3Þ