J. Eur. Opt. Society-Rapid Publ. 21, 50( 2025) 189
Fig
. 1. Schematic diagram of a Al / Mo / SiC multilayer grating with N = 4 in( a) classical and( b) conical mountings. For classical mounting the diffracted orders are in the plane of incidence hYZi. For conical mounting,( c) and( d) represent projections of + 1 order in hYZi and hXZi planes, respectively.
Fig
. 2. Variation of the diffracted angle /( a) with grazing angle h i at k = 0.154 nm and( b) with wavelength at h i = 45 degrees in case of classical mounting. The dots in( b) correspond to diffracted angles measured at SOLEIL synchrotron.
17 – 25 nm at an incident angle of 45 degrees in a classical configuration. As expected, the 0 order corresponds to specular reflection and its angle is constant, while ± 1 orders demonstrate the wavelength-dependent diffraction behavior of equation( 1).
Figures 3a and 3b show the diffraction angles / i and w i computed respectively from equations( 1) and( 2) for the conical configuration. The calculation was performed for an incident angle of 45 degrees. The zero-order angles are consistent with specular reflection. Due to the symmetry relative to the plane of incidence( plane( YZ) inFig. 1), the / i diffraction angles for ± 1 orders are identical; their values remain close to the specular reflection( O order) and decrease slightly with increasing wavelength( Fig. 3a). In contrast, at Figure 3b the / i diffraction orders for ± 1 order have opposite values with a significant wavelength-dependence.
The diffraction angles measured for the �1 and + 1 orders of the periodic N = 16 ML grating at SOLEIL synchrotron are also plotted in Figures 2b and 3b They show a good agreement with theoretical values, with a difference of less than 0.05 degree, which remains within the accuracy of alignment of the sample(± 0.1 degree).
In conclusion, in the classical mounting, the difference in peak wavelength observed between the + 1 and �1 diffraction orders arise naturally from their different diffracted angles and the corresponding Bragg conditions. This will also result in a difference in the diffraction efficiency of the + 1 and �1 orders. By contrast, the conical configuration is geometrically symmetric; therefore, we expect the