JEOS RP ISSN02 | Page 185

180
Z is the space coordinate along the direction of propagation. Finally, the twin photon flux writes:
N twin ðZÞ ¼ N s ðZÞ ¼ N i ðZÞ ¼
Z þ1
0 dx N s ðx; ZÞ: ðB4Þ
For low pump intensities, all the spectral components are verifying
ð Þ2 eff
2p f ð2Þ ðxÞ 2 I p ð0Þv 2
kðxÞ2, and an analytical expression of the
4 generated twin-photon flux can be deduced, i. e.:
pffiffiffiffiffiffiffiffi
lim jC ð2Þj 1
N twin ðZÞ
2 p 2 v ð2Þ eff 2 0 cn p n s n i k 2 s jjI a Z: p ðB5Þ
Note that this expression is equal to equation( 8) by a multiplicative factor of p, which is an additional validation of our semiclassical model.
Appendix C: The nonlinear Hamiltonian model
The nonlinear Hamiltonian model( NHM) describes the quantum fieldintermoftimedependentfield mode operators assuming the undepleted pump approximation [ 12 ]. The Heisenberg’ sequa- tion of motion propagates those quantum fields through time. A variable change z ¼ ct gives the spatial dependency. Two intensity regimes can be defined, one being linear, the other one exponential, which gives for the twin photon flux [ 12 ]:
8
2v ð2Þ2 eff n gs n gi r 2 2 p
><
N twin ðZÞ ¼
0 n 2 s n i 2 n p k 2 n s g r 2 s þ I 2r2 p ð0ÞZ; ðsmall I p Þ
p c >: expð2j time ZÞ; ðhigh I p Þ
2Ln s
J. Eur. Opt. Society-Rapid Publ. 21, 48( 2025)
ðC1Þ
� N twin ¼ N 2 � N dark
2
�
N 3 � N dark
2N 23
3 ðD2Þ The quantities N dark i are measured by rotating the pump polarization angle of 90 °: they correspond to coincidences generated by parasitic ambient light. With these equations, it is possible through statistical measurements to measure T 2, T 3 and then N twin which is the real twin photon flux corrected from the losses. The numerical aperture of the collection device is empirically dimensioned so that the pump beam radius equals the aspherical lens pupil radius, the geometry of the SPDC collected mode then corresponding to the geometry of the pump beam mode.
For the nanosecond experiment, the collection set-up is the same as in the SPDC experiment, the losses being calibrated by comparison with the CW absolute measurement at equal intensities.
For the picosecond experiment, the generated flux, for example when pumping at 1 GW cm �2, are sufficient to have a macroscopic measurement available with a pico-joulemeter Molectron J3S10. This is used as a quantitative reference: a measurement at the same pump intensity is then realized with SNSPDs and calibrated neutral densities. By doing this, the coupling is easily and very accurately measured. Here again, the collection numerical aperture is dimensioned to collect the same geometrical spatial mode than the pump beam, for both the Molectron and SNSPD measurements. Thus, the pump intensity can be investigated at smaller values, the coupling efficiency being assumed to not depend on the pump intensity. Note that the calibrated neutral densities are always chosen so that the average number of photons per pulse is small versus 1, in order to certify the linearity of the SNSPD response.
Appendix E: Calculation of the D 2 error quantifier
In low gain regime, we chose to neglect the horizontal error which is small compared to the vertical one, so that it comes: with j 2 time ¼ p 2 v ð2Þ 2 r 2 2 eff p
4 0 cn s2 n i2 n p k 2 r 2 p s þ I 2r2 p: p ðC2Þ
The quantities r p; s are the transverse section of both pump and down-converted fields, n gs; i are the group velocity indices of signal and idler, and n g ¼jn gs � n gi j.
Appendix D: Detection method
For the CW experiment, coincidence measurement is used between detector 2 and detector 3. The absolute fiber coupling is measured by comparing the coincidence to single ratio of detectors 2 and 3 [ 12 – 16 ]. The transmissions of channel 2 and 3 are written T 2 and T 3, respectively: they include all common optical losses, the coupling efficiency in the fiber, and the detectors efficiencies. If N 2 and N 3 are the flux of detection events on detector 2 and detector 3, and N 23 the flux of joint detection events between detector 2 and detector 3, then straightforward statistical calculations lead to [ 12 – 16 ]:
2 lowgain ¼ 1 X number of data i
�
N measured theory 2 twin i
� N twin i:
2 r verticali
r vertical i stands for the error on the measurement of the twin photon flux( vertical error bars on Fig. 3).
In high gain regime, the horizontal error bars are predominant, which gives:
2 highgain ¼ 1 X number of data i
2
I injected theory p
� I i p i
:
2 r horizontali
r horizontal i corresponds to the horizontal uncertainty. I injected p and i are the intensities that leads to the same value of twin
I theory p i photon flux N i twin.
T 2 ¼
2N 23 N 3 � N dark
3
; T 3 ¼
2N 23 N 2 � N dark
2
; ðD1Þ