JEOS RP ISSN02 | Page 178

J. Eur. Opt. Society-Rapid Publ. 21, 48( 2025) 173
Fig. 1. Experimental setup used for performing CW, nanosecond and picosecond Type II SPDC in a x-cut KTP crystal.( e p, e s, e i) stand for the polarizations of the pump, signal and idler beams, respectively.
Table 1. Characteristics of the pump lasers.
Pump source
Spectra( CW)
Coherent( ns)
Continuum( ps)
Wavelength
532 nm
527 nm
532 nm
Pulse duration
NA
200 ns
15 ps
Repetition rate
NA
1 kHz
10 Hz
Focusing lens [ mm ]
500
500
750
2 x Rayleigh length [ cm ]
7.2
70
9.4
Waist radius [ lm ]
78
250
90
Energy / pulse [ mJ ]
NA
1.3 – 20
0.3 – 11
Three different laser sources, Spectra Physics Millenia eV, Coherent Evolution 30 and Continuum, were used interchangeably. Each of them emits a single transverse Gaussian mode beam. Table 1 summarizes their temporal, spatial and energetic characteristics.
The intensities given in Table 1 are calculated from the waist radii given in the same table.
A half-wave plate( HWP) allowed to polarize the pump beam along the y-axis of KTP. The pump beam was focused using an optical lens( L1) into a 1-cm-long x-cut KTP. L1 was chosen so that the Rayleigh length of the pump beam, deduced from the beam waist radius, is greater than the length of the crystal. By this way, the SPDC experiment was performed with parallel beams. The generated beams were further collimated with an optical lens( L2), filtered with a filter-set( F) including notch filters to reject the pump and injected into a single mode fiber( SMF) by use of an aspheric lens( AL). The focal length f 2 of lens L2 was always chosen so that the pump beam size fits well the aspherical lens diameter to maximize the injection efficiency of the SPDC signal in the SMF. Note that the use of single mode fibers associated to the collection lens( L2) with small numerical aperture( 0.041 for the CW and ns setups, 0.030 for the ps setup) allows the collinearly propagating component to be spatially selected, and so prevents any non-colinear contributions of SPDC to be collected. For each pump source, the pump intensities were varied using neutral densities.
Highly sensitive MoSi Superconducting Nanowire Single Photon Detectors( SNSPDs) from IDQuantique were used as detectors. The configuration of the detection stage depends on the pump source. For the CW and kHz ns lasers( solid lines in Fig. 1), the signal was separated on a balanced Beam Splitter( BS) and coincidence measurements were performed on channel 2 and 3. In the case of the ps pump laser, the detection on channel 1 was triggered by the signal of a photodiode DET 110( Thorlabs) installed on a leak of the pump laser and used as external trigger( dotted line in Fig. 1). All the detectors are properly calibrated. For the CW experiment, the absolute twin photon flux as well as the losses were simultaneously deduced by comparing the coincidence to single ratio [ 16 ] as described in Appendix D. The nanosecond experiment losses were calibrated from the overlapping intensities with the CW absolute measurement. The losses in the picosecond regime are calibrated from a high energy free space measurement whose collection numerical aperture equals that of the SMF collection set-up, as described in Appendix D.
2.2 Theory
We proposed a semi-classical model, the so-called SCM, where the field motion is governed by the coupled wave amplitudes system coming from Maxwell’ s equations, the initial conditions being the pump field at the entrance of the medium and the quantum fluctuations of vacuum at