J. Eur. Opt. Society-Rapid Publ. 21, 46( 2025) 159
Figure
2. a) QPMC of USPDC and SHG-SPDC processes. b) Map of theoretical positions for QPMC for USPDC and SHG- SPDC and experimental photon counting for different PPLN temperatures. The power at 1064 nm is 4.55 W at the input of the PPLN. c) Calculated variations of QPMC with PPLN temperature, corresponding measured photon count peak positions. The red star corresponds to optimal SFG PPLN temperature.
photons with a wavenumber of 2k p. Thisisfollowedby phase-matched SPDC, which generates photons with wavenumbers k s and k c. This process is known as SHG- SPDC. Even if SHG is not phase-matched, strong pump power combined with the non-perfect poling of the PPLN crystal induces enough SHG power to trigger the SPDC. The corresponding QPMC are:
k SHG�SPDC ¼ 2k p � ðk s þ k c Þ 1 � k c h 2 c k s 2
� 2p K ¼ 0:
Vectorial charts of the two processes can be seen in Figure 2a. Other processes are susceptible to happen, such as Raman scattering [ 14 ] or thermal emission [ 15 ]. We believe that thermal emission will not generate significant parasitic photons in the band of interest. However, upconverted Raman lines at D m = ± 260 cm �1 and ± 630 cm �1 could potentially be generated [ 16 ], especially at high pump / signal power. Some examples of QPM calculation are shown on Figure 2b and Figure 2c with dashed lines, for different values of the photon emission angle ðh c) and varying PPLN temperatures.
By sending only the 1064 nm laser into the PPLN, we experimentally observe USPDC and SHG-SPDC photons on the camera. Figure 2b shows image acquisitions for different PPLN temperatures with a constant pump laser power of 4.55 W at the PPLN input. We see a maximum photon counts at different positions( defined by wavelength and angle of emission), corresponding to the conditions where QPMC is satisfied for the different processes. The USPDC process results in emission around 633 nm which aligns well with the calculated QPMC from the above equations. Additionally, we identify the emission in the 570 – 600 nm range( central circles in Fig. 2b) as the SHG- SPDC process, which corresponds to the generation of two distinct photons from two SPDC photon pairs. The fact that the circles are filled with photons is explained by the fluorescence cone of the SPDC, generating photons at a given wavelength along a ring. The diffraction grating of our setup then diffracts all the photons of a given wavelength along a vertical line.
Figure 2c shows the theoretical and experimental collinear QPMC, for h c = 0 ° with respect to PPLN temperatures. The agreement remains extremely good without any scale adjustments on spectral or angular axis. The photon emission around 549 nm might correspond to the second Stokes line of the pump, followed by a SHG process. Other Raman lines could potentially be observed without the longpass filter F1. Another possibility would be the SHG-SPDC process, which should be paired with an emission in the far infrared around 17.3 lm. This emission at 549 nm is anyway far away from the signal of interest at 632.7 nm and could easily be filtered out, as well as the emission around 590 nm due to SHG-SPDC process. Therefore, we did not further analyze these processes quantitatively and instead focused on the USPDC-generated photons, as this is the only process that could potentially interfere with the quantum system centered at the SFG wavelength.
4 Spectral noise quantification
This section is focused on the quantitative analysis of parasitic photons emitted through the USPDC process. The broadband nature of the emission of these parasitic photons implies that the useful metric is the noise spectral density whose unit is the number of photons generated per second and per GHz of spectral band at the wavelength of interaction( s �1 GHz �1). Figure 3a shows the spectral photon density close to 632.7 nm when only the pump laser at 1064 nm is sent through the PPLN, and for different pump powers. The emitted photons correspond to the USPDC process. The photons are integrated vertically between �20 and 20 mrad for a PPLN temperature of 56.8 ° C. As expected, we can see that the parasitic emission varies with the pump power. Figure 3b( red triangles) represents the average photon generation rate at the SFG wavelength measured in a 1-GHz-bandwidth versus pump