JEOS RP ISSN02 | Page 148

J. Eur. Opt. Society-Rapid Publ. 21, 45( 2025) 143
way and tackle the reconstruction strengths and drawbacks of different solvers, taking into account also the optical properties of the chosen imaging system [ 16 ].
In this paper, we propose a method to simulate the numerical phantom of a cell suitable for different cell lines at different levels of complexity. Our objective is to model the 3D Refractive Index distribution of important classes of cells and some internal organelles, with the aim to use this flexible cellular model to tailor algorithms relative to the entire holo-tomographic imaging pipeline. In particular, we apply the method by simulating 1) the RI distribution of a yeast cell with cytoplasmic vacuoles inside, based on the studies reported in [ 17 ], 2) of a monocyte with Lipid Droplets( LDs) based on the findings reported in [ 18 ], 3) of a monocyte with vacuoles, merging the data from the first two simulations and 4), of a monocyte with lysosomes, based on the studies reported in [ 19 – 21 ]. As will be discussed in the next sections, the choice of this selection of samples is linked to their significance for basic research in biology and diagnostics and is due to the availability of prior information from experimental tests carried out by different groups. The whole method is however applicable to a larger variety of cells and organelles, provided that prior statistical information is available on the morphometry and RI of the sub-compartments to be simulated. We share the simulated dataset of 200 cells in suspension with the aim of providing a tool for the development of phasecontrast tomography algorithms in the absence of a ground-truth.
1.1 Selected case study cells
Yeast cells are important eukaryotic cells used as a model for the study of cytoplasmic vacuoles. At any stage of their life cycle, they are characterized by the presence of a large roundish vacuole along with the potential presence of much smaller vacuoles with low RI values. In mammalian cells, e. g. in monocyte cells of the bloodstream, the presence of various phenotypes of cytoplasmic vacuoles( that can vary largely in number and size) is considered as a biomarker for several disfunctions and pathological conditions, e. g. in lysosomal storage diseases( LSDs) [ 22 ], SARS-CoV-2 [ 23 ] and other viral infections [ 24 – 26 ], and cancer [ 27 – 31 ], to name a few. Thus, there is a strong interest in phenotyping patterns of cytoplasmic vacuoles and lysosomes inside these cells, some of them challenging the optical resolution of holo-tomographic flow cytometry systems. Since it is possible to experimentally control the volume and the number of cytoplasmic vacuoles, engineering the yeast cells acting on the osmotic conditions of the surrounding buffer, or in the case of mammalian cells by using external drugs to simulate this phenotype, it is important to implement a simulation method capable of describing all these conditions. Accordingly, particular attention was put in the simulation of cytoplasmic vacuoles. Instead, LDs are intracellular compartments mainly located in the cytoplasm [ 32 ]. LDs represent small structures with high RI values linked to several regulatory mechanisms in living cells, both in physiological and pathological states. Generally, they present a high numerosity. They were initially recognized only as storage organelles, but it has been discovered that they play multiple roles in maintaining intracellular homeostasis and that they dynamically interact with various organelles, such as mitochondria and lysosomes, thus affecting cellular processes [ 33 ]. For this reason, the involvement of LDs has been recognized in several pathologies, such as cancer [ 34 ], diabetes [ 35 ], or neurodegenerative diseases [ 36 ]. In immune cells( e. g., monocytes) LDs are markers of viral infections [ 37 ] and inflammations [ 38 ], as their number and size increase in response to these stimuli.
Aside from the specific organelles modeled, the simulation of monocytes is of primary interest in general as, like all the other cells of the blood stream, they naturally live in suspension. Consequently, this class of cells is the one that benefits the most from the use of a holo-tomographic apparatus working in flow cytometry mode, for which the absence of a ground-truth is a non-negligible impairment. The statistics of these simulations were studied and extracted from the literature and from data measured by the holo-tomographic flow cytometry system on suspended cells.
2 Methods
We developed a versatile algorithm for generating numerical phantoms of suspended cells, which we then tailored to simulate the unique characteristics of various cell lines as described in the previous sections. Accordingly, four representative simulations are here discussed: yeast cells with cytoplasmic vacuoles( Simulation 1), monocytes with LDs( Simulation 2), monocytes with vacuoles( Simulation 3) and monocytes with lysosomes and cytoplasmic vacuoles( Simulation 4). For each simulation, different classes of substructures were considered. Three substructures are common to each simulation, in particular: external membrane, cytoplasm and nucleus. In addition, vacuoles are simulated for Simulations 1, 3 and 4, LDs for Simulation 2 and lysosomes for Simulation 4.
2.1 Numerical simulation of a phantom cell
The first simulative step consists in creating a box region of 200 200 200 pixels, with pixel size 0.125 lm, where the cell will be inserted. To obtain a model as realistic as possible, the dimension and the shapes of the overall cell and of each intracellular structure were varied for each realization and drawn from distributions of real samples [ 17 – 21, 39, 40 ]. Figure 1 sketches the steps to generate the structures common to all cell types. The external shape of the cell is obtained by drawing its volume and sphericity index from a realistic distribution [ 17, 18, 39, 40 ] and adapted to the physical dimension of the cells of interest( yeast cell [ 17 ] or monocyte [ 18 ]), as shown in Fig. 1a. Concerning the yeast cells, they occupy around 1 / 3 of the modelled volumetric box region. Monocytes are bigger and occupy around 60 % of the simulated volume. Once those values are calculated, the cell is initially modeled as an ellipsoid whose semiaxes in a Cartesian coordinate system are labelled as r x, r y and r z. Ther x value is drawn from a Gaussian distribution