116
J. Eur. Opt. Society-Rapid Publ. 21, 42( 2025)
Fig. 6. The relationship between the BER and the received power of PD1 and PD2.( a) Downlink;( b) Uplink.
Fig
. 7. Eye diagram at a different transmission distance.( a) BTB;( b) 10 km;( c) 20 km;( d) 37 km.
k = 1552.52 nm the maximum transmission distance is obtained to be 37 km by equation( 15).
Figure 7 is the eye diagram obtained at different transmission distances in the conventional frequency octupling ROF system. From Figure 7, we can see that the width of the code word becomes narrower and narrower as the transmission distance increases. The eye diagram is almost closed when the distance is 37 km. These results are in agreement with equation( 15).
To compare our scheme with the conventional scheme, we give the eye diagrams at different fiber transmission distances for our designed system in Figure 8. From Figure 8, we can see that the eye diagram is still open even the transmission distance reaches 80 km.
4.4 Compare the conventional carrier reuse system with our scheme
When the OS is on and the ES is off, the system is the conventional carrier reuse system. The central frequency of the FBG is shifted to 193.06 THz, which is the frequency of the �4th order optical sideband.
Figure 8 is the relationship between BER and the received powers of the PD1 in the conventional carrier reuse system and our system.
We can see from Figure 9 that the improvements in receiver sensitivity are increased with the fiber transmission distances. Under the condition of BER = 10 �9, theimprovement of the sensitivity of receivers is listed in Table 2.
5 System stability
The values of the parameters of the main devices are chosen based on the values of the theoretical analysis or the default values of the simulation system. In practice, the parameters affecting the BER( or Q-factor) mostly are,( 1) the amplitude of the RF drive signal, which determines the modulation index of PolM and thus affects the amplitude of the sidebands;( 2) the modulation index P of the PM and the amplification factor G of the EG, they are the key parameters which realize the data is modulated to the + 4th order sideband only;( 3) the polarization angle of the Pol;( 4) the value of the 90 ° EPS, which is the key parameter to determine whether the odd terms in the 2n-order sidebands in the output of the PolM1 and PolM2 can be canceled each other. When their values deviate from their theoretical values or default values, the BER is bound to increase. To ensure the BER < 10 �9, it is necessary to investigate the range within which these parameters are allowed to deviate from their theoretical or default values.
5.1 The influence of V RF on the Q-factor
According to the previous theoretical analysis, the theoretical value of the m is 2.405. When m varies in the range of 2.268 < m < 2.551, according to m =( V RF / V p) p( the default value of V p is 1 V in the simulation system), the corresponding range of the V RF is 0.7155 < V RF < 0.8155. When the V RF varies in this range, the relationship curve