2. Healing abutments were placed and allowed
to heal 5. Radiograph was taken to confirm the seating
of coping inside the implant
3. After 10 days, healing abutments are
removed 6. The copings were rigid splinted with the help
of floss and composite/pattern resin
4. Pick up impression copings were placed 7. A stock impression tray was selected and a
window was opened up to expose the copings
out of the tray
8. Tray was checked inside the oral cavity