Table 5. Comparison of Antibody Clones Used with IHC
Study Takeuchi et al., 2009 No. of Antibody Specimens Clone +
(% of ALK )
Antigen Retrieval Target Retrieval Solution (pH 9.0) (for all)
Detection/ Amplification System iAEP
Scoring 0 vs. + (for all)
Standard RT-PCR
IHC Sensitivity 100%
IHC Specificity 100%
(vs. Standard) (vs. Standard)
21 (52%)
5A4
5A4 ALK1 ALK1 SP8 SP8 Rodig et al., 2009 239 (4%) ALK1 ALK1 MinoKenudson et al., 2010 37 (59%) ALK1 EDTA in pressure cooker (for both) EDTA in pressure cooker (for both)
EnVision+ iAEP EnVision+ iAEP EnVision+ EnVision+ Tyramide amplification EnVision+ (for both) Score >2.7 on image analysis is positive 0 vs. + (for all) FISH 0 vs. + (for both) FISH
27% 100% 9% 20% 100% 40% 80% 67%
100% 100% 100% 100% 18% 100% 100% 97%
D5F3 Murakami et al., 2011 361a (5%) ALK1 Target Retrieval Solution (pH 9.0) (for all) ABC (no enhancement) EnVision FLEX+ EnVision FLEX+ Conklin et al., 2013 377 (3%) 5A4 According to manufacturer’s instructions (for all) iAEP 0, 1+, 2+, or 3+ (for all) FISH RT-PCR/ FISH
100% 81%
99% 100%
5A4
100% 100% 100%
100% 99.7% 62.5%
ALK1 ALK1 5A4 D5F3 Selinger et al., 2013 594 (11%) ALK1 Buffer (pH 9.0) in pressure cooker According to manufacturer’s instructions According to manufacturer’s instructions
EnVision FLEX ADVANCE ADVANCE ADVANCE EnVision FLEX+ ultraView and ultraView Amplification OptiView and OptiView Amplification 0, 1+, 2+, or 3+ (for all) FISH
66% 66% 100% 100% 100%
100% 87.5% 87.5% 75% 99%
5A4
100%
98%
D5F3
100%
99%
a