SERVOTOUGH OxyExact 2200
SERVOTOUGH SpectraScan 2400
SERVOTOUGH SpectraExact 2500
SERVOTOUGH OxyExact 2200
HAZARDOUS AREA
HIGH SPEC PROCESS O 2 ANALYZER OFFERS SAFE OR HAZARDOUS AREA CONTROL WITH UP TO SIX TRANSMITTERS
The OxyExact 2200 high specification O2 analyzer offers an unrivaled combination of precision, flexibility and performance for optimum process and safety control. The OxyExact can be configured with a safe or hazardous area control unit with up to six transmitters.
|
GAS |
|
O 2 |
|
OXYGEN |
|
|
MEASURES
%
PERCENT
|
APPLICATION
PROCESS CONTROL
|
Zone 1 certified to ATEX Cat 2, IECEx and FM / CSA Class 1 Div 1
Three enclosure systems allow sampling of any flammable gas up to 100 % O2 and pressures of up to 40psi
High temperature version eliminates the need to condense hot sample prior to analysis
SENSING TECHNOLOGY
SAFETY
SERVOTOUGH SpectraScan 2400
HAZARDOUS AREA
REVOLUTIONARY INLINE REAL- TIME ANALYSIS OF HYDROCARBON COMPONENTS C1-C6
A real time optical analyzer utilizing the Precisive field proven optical bench, the SpectraScan 2400 delivers a breakthrough capability in the continuous analysis of light hydrocarbons C1-C6.
|
|
|
|
GAS
CO
CARBON MONOXIDE
CO 2
|
|
CARBON DIOXIDE |
MEASURES
%
PERCENT
CV
CALORIFIC VALUE
|
APPLICATION
PROCESS CONTROL
|
North American Cat 1, Div 2 ATEX Cat 3 IECEx Zone 2
Tunable band-pass filter enables simultaneous scanning of selected wavelength bands for gases including Methane, Ethane, Propane and iso-Butane
Unique tunable filter process with IR photometer technology delivers industryleading interference compensation
C1-C6
H 2 S
HYDROGEN SULFIDE
SENSING TECHNOLOGY
QUALITY
SERVOTOUGH SpectraExact 2500
HAZARDOUS AREA
RUGGED PHOTOMETRIC GAS ANALYZER FOR DEMANDING PROCESS APPLICATIONS
Servomex’ s iconic industry-leading photometric analyzer delivers flexible single and multi-component gas analysis capability for corrosive, toxic and flammable sample streams. The SpectraExact 2500’ s reliable, accurate and stable real-time online process analysis makes it ideal for a range of process, combustion and emissions gas analysis applications.
ATEX, IECEx and North American hazardous area approvals
Easy integration with DCS – from 4-20mA to Modbus TCP
Sample cell and electronics segregated – for easy maintenance and safe operation
GAS
TOXIC
?
FLAMMABLE
?
CORROSIVE
?
MEASURES
%
PERCENT ppm TRACE
SENSING TECHNOLOGY
APPLICATION
PROCESS CONTROL
P18 SERVOPRO NOx, SO 2 and HFID products are also available. Please contact Barbara Marshik( bmarshik @ servomex. com) for more information.