Johnson Controls expands thermal management offering
OptiCool launches RDHx for AI and HPC workloads
OptiCool Technologies has launched its new 120kW Rear Door Heat Exchanger( RDHx) – the highestcapacity rear door heat exchanger( RDHx) on the market. Capable of removing up to 120kW per rack, it’ s purpose-built to meet the extreme thermal demands of nextgeneration AI and HPC workloads. Engineered for seamless retrofit into existing environments, the new 120kW Rear Door Heat Exchanger – the highest-capacity unit of its kind – supports rack densities of up to 120kW and removes the need for separate zones or major infrastructure overhauls. Its proprietary two-phase refrigerant design, based on the thermodynamics of phase change, removes heat from the rack and returns it into the space at room
neutral ambient temperature. This launch expands OptiCool’ s existing RDHx lineup( 30kW and 60kW), delivering a modular, high-capacity option for operators balancing density, uptime, and energy use. OptiCool’ s Rear Door Heat Exchanger system requires significantly less energy than traditional air-based cooling approaches, helping operators reduce cooling costs and improve energy efficiency. The 120kW Rear Door Heat Exchanger leverages the same ultra-efficient design principles as OptiCool’ s lowercapacity units, which have achieved power usage effectiveness( PUE) as low as 1.02 in tested deployments. This helps data centers advance ESG goals while preparing for nextgeneration compute demands.
Johnson Controls( JCI) has expanded its data center thermal management offerings with the launch of its Silent-Aire Coolant Distribution Unit( CDU) platform. This latest addition to Johnson Controls’ end-to-end thermal management portfolio enables data centers to seamlessly transition to liquid cooling as rack densities rise. The Silent-Aire CDUs offer a wide range of scalable cooling capacities from 500kW to over 10MW in flexible designs that are uniquely tailored to suit the needs of any data center deployment. With the rapid growth of AI and increasing demand for computing power, denser chips are generating more heat, making cooling innovation a critical priority. Silent-Aire CDUs allow for precision cooling of this equipment, enabling
data center owners and operators to deploy the latest in semiconductor technology. Positioned either inrow adjacent to heat-generating equipment or in the whitespace perimeter, Silent-Aire CDUs are designed for flexibility to support a wide range of liquid-cooling configurations and hybrid designs to deliver precise, efficient cooling of high-performance environments ranging from edge-based inference to large AI factories. This launch builds on Johnson Controls’ broad portfolio of existing Silent-Aire, York, and M & M Carnot thermal management products that serve data centers worldwide. By adopting Johnson Controls’ comprehensive thermal management solutions, owners and operators can significantly improve total facility efficiency.
Modine opens India facility
Modine ®( MOD), a diversified global leader in thermal management technology and solutions, officially opened its new 100,000 ft 2 facility in Chennai,
India. The event marked the beginning of full-scale, in-region production of Airedale by ModineTM data center cooling equipment and a strategic positioning to meet accelerated demand from data center customers across the Asia-Pacific( APAC) region. The launch event featured remarks from senior leadership, a tree-planting ceremony, and the unveiling of the first locally manufactured unit— the AireWall ONE™ fan wall. Completed on schedule, the unit features 70 % locally procured components, and the team is actively working to increase local sourcing. More ranges are being incorporated into the production schedule to match
increasing data center demand across the Asia Pacific region, which analysts believe is growing at a compound annual growth rate( CAGR) of 13 %. The state-of-the-art facility in Chennai complements Modine’ s recently announced investment to expand U. S. production, reinforcing the company’ s strategy to serve high-growth markets. The increasing use of AI applications has driven demand for Airedale by Modine data center cooling solutions, including high-efficiency chillers, indoor air systems, next-generation liquid cooling technologies, intelligent controls, building management systems( BMS), and a global service network.
Alfa Laval and AquaGreen sign MoU
Alfa Laval and AquaGreen have officially signed a Memorandum of Understanding( MoU) to strengthen collaboration in the transformation of biomass and waste into renewable thermal energy and biochar. This strategic partnership marks a significant step forward in advancing sustainable water and waste management technologies. By combining Alfa Laval’ s expertise in decanter centrifuge technology with AquaGreen’ s innovative Integrated Drying & Pyrolysis( IDP) system, the two companies aim to deliver comprehensive, high-efficiency solutions for sludge dewatering, CO 2 reduction, carbon sequestration, elimination of environmental pollutants, and resource recovery. The collaboration supports municipalities and industries in meeting their environmental goals while contributing to the circular economy. The MoU outlines joint activities including market development, technology innovation, after sales services, and knowledge sharing, with a focus on delivering integrated solutions that reduce environmental impact and promote long-term sustainability. www. heat-exchanger-world. com Heat Exchanger World October 2025