Healthcare Hygiene magazine June 2021 June 2021 | Page 46

The ANTT framework of practice , created by
Stephen Rowley and Simon
Clare , provides a method to teach clinicians the foundational aspects and practical application of aseptic technique , an area of practice and education that can aid infection control and prevention .
• type , sterile or non-sterile , and packaging , multi-use bottle or single packet gel . New types of transducer covers , and separating dressings , provide options that eliminate or remove gel from the needle puncture site . Procedural areas free from gel eliminate a level of infection risk , reduce post insertion contamination , and can significantly speed clean-up .
The aseptic no-touch or non-touch technique ( ANTT ) is gaining acceptance as a safe and consistent practice for percutaneous procedures . In a critical review of Infection Control Policies by Daugherty and Blebea in 2021 , they supported the use of low-level disinfection and the aseptic no-touch technique with transducer / probe cover protection and gel removal or separation prior to puncture . The goal of ANTT is to maintain asepsis of the prepared skin puncture area , needle , tip of the syringe , and other key covered device parts , while performing the clean procedure , as applicable to ultrasound guided peripheral catheter insertions . The ANTT framework of practice , created by Stephen Rowley and Simon Clare , provides a method to teach clinicians the foundational aspects and practical application of aseptic technique , an area of practice and education that can aid infection control and prevention .
Nancy Moureau , RN , PhD , CRNI , CPUI , VA-BC , is the chief executive officer at PICC Excellence , Inc ., a research member of the Alliance for Vascular Access Teaching and Research ( AVATAR ) Group , and an adjunct associate professor at Griffith University in Brisbane , Australia .
References :
Abdelfattah R , Al-Jumaah S , Al-Qahtani A , Al-Thawadi S , Barron I , Al-Mofada S . Outbreak of Burkholderia cepacian bacteremia in a tertiary care centre due to contaminated ultrasound probe gel . J Hosp Infect 2018 ; 98 ( 3 ): 289-94 .
Adhikari S , Blaivas M , Morrison D , Lander L . Comparison of infection rates among ultrasound-guided versus traditionally placed peripheral intravenous lines . J Ultrasound Med 2010 ; 29 ( 5 ): 741-7 .
AIUM . Guidelines for Cleaning and Preparing External and Internal-Use Ultrasound Transducers and Equipment Between Patients as well as Safe Handling and Use of Ultrasound Coupling Gel ; 2020 . https :// www . aium . org / officialStatements / 57 .
American Institute of Ultrasound in Medicine Practice Parameter for the Performance of Selected Ultrasound Guided Procedures . 2014 ; www . aium . org / resources / guidelines / usguidedprocedures . pdf . Accessed December 16 , 2020 .
American Institute of Ultrasound in Medicine . Guidelines for Cleaning and Preparing External- and Internal-Use Transducer and Equipment Between Patients as well as Safe Handling and Use of Ultrasound Coupling Gel . http :// www . aium . org / OfficalStatements / 57 .
Bahl A , Hijazi M , Chen NW , Lachapelle-Clavette L , Price J . Ultralong versus standard long peripheral intravenous catheters : a randomized controlled trial of ultrasonographically guided catheter survival . Annals of emergency medicine . 2020 Aug 1 ; 76 ( 2 ): 134-42 . https :// doi . org / 10.1016 / j . annemergmed . 2019.11.013
Basseal J , Westerway S , Hyett J . Analysis of the integrity of ultrasound probe covers used for transvaginal examinations . Infection , Disease , and Health . 2020 ; 25:77-81 .
Blanco P . Ultrasound-guided peripheral venous cannulation in critically ill patients : a practical guideline . The ultrasound journal . 2019 Dec ; 11 ( 1 ): 1-7 . https :// doi . org / 10.1186 / s13089-019-0144-5
Carrico R , Furmanek S , English C . Ultrasound probe use and reprocessing : Results from a national survey among U . S . preventionists . American Journal of Infection Control . 2018 ; 46:913-20 .
Centers for Disease Control . Chemical Disinfectants , Guideline for Disinfection and Sterilization in Healthcare Facilities ( 2008 ). www . cdc . gov / infection control / guidelines / disinfeciton / disinfection-methods / chemicals . html . Accessed May 25 , 2021 .
Centers for Disease Control . Guideline for Ultrasound Transducer Cleaning and Disinfection . https :// www . cdc . gov / infectioncontrol / guidelines / disinfection / cleaning . html . Accessed May 25 , 2021
Cervini P , Hesley G , Thompson R , Sampathkumar P , Knudsen J . Incidence of Infectious Complications After an Ultrasound-Guided Intervention . AJR 2010 ; 195:846-50 .
Clare S , Rowley S . Implementing the Aseptic Non Touch Technique ( ANTT ®) clinical practice framework for aseptic technique : a pragmatic evaluation using a mixed methods approach in two London hospitals . J Infect Prev . 2018 Jan ; 19 ( 1 ): 6-15 . doi : 10.1177 / 1757177417720996 . Epub 2017 Aug 4 . PMID : 29317909 ; PMCID : PMC5753945 . https :// doi : 10.1177 / 1757177417720996
Costantino T , Parikh A , Satz W , Fojtik J . Ultrasonography-guided peripheral intravenous access versus traditional approaches in patients with difficult intravenous access . Annals of Emergency Medicine , 2005 , 46 ( 5 ): 456-461 . https :// doi . org / 10.1016 / j . annemergmed . 2004.12.026
Daugherty SF , Blebea J . The Need for Participation in Development and Critical Review of Recommendations for Infection Control Policies Involving Vascular Ultrasound . Journal of Vascular Surgery : Venous and Lymphatic Disorders . 2021 Mar 15 . https :// doi . org / 10.1016 / j . jvsv . 2021.02.017
Drafz M , Goeller K , Dizon B , Buc D , Moureau N . Efforts Toward Standardization of UGPIV Insertion through Quantitative Clinical Product Evaluation ( UltraDrape ). Association for Vascular Access Annual Scientific Conference ; Scientific Abstract Poster October 5 , 2019 ; Las Vegas , NV .
Egan G , Healy D , O ’ Neill H , et al . Ultrasound guidance for difficult peripheral venous access : systematic review and meta-analysis . Emergency Medicine Journal 2013 ; 30:521-526 . https :// emj . bmj . com / content / 30 / 7 / 521
Gorski L , Hadaway L , Hagle M , Broadhurst D , Clare S , Kleidon T , Meyer B , Nickel B , Rowley S , Sharpe E , Alexander M . ( 2021 ) Infusion Therapy Standards of Practice , 8th Edition . Journal of Infusion Nursing . 2021 ; 44 ( 1S ): S1-S224 . https :// doi : 10.1097 / NAN . 0000000000000396
Guideline for Ultrasound Transducer Cleaning and Disinfection [ policy statement ]; 2018 . https :// www . acep . org / patient-care / policy-statements / guideline-for-ultrasound-transducer-cleaning-anddisinfection / Accessed May 25 , 2021 .
Moureau N , Gilbert GE . Survey of ultrasound-guided peripheral intravenous practices : a report of supply usage and variability between clinical roles and departments . J Assoc Vasc Access . 2020 ; 25 ( 3 ): 1 – 11 ; https :// doi : 10.2309 / java-d-20-00021
Oleszkowicz S , Chittick P , Russo V , Keller P , Sims M , Band J . Infections Associated with Use of Ultrasound Transmission Gel : Proposed Guidelines to Minimize Risk . Infection Control and Hospital Epidemiology . 2012 ; 33:1235-7 .
Rutala W , Weber D . Guideline for Disinfection and Sterilization in Healthcare Facilities ( 2008 ).
Society of Diagnostic Medical Sonographers . Guidelines for Infection Prevention and Control in Sonography : Reprocessing the Ultrasound Transducer . J Diag Med Sonog 2020 ; 36:381-403 .
Solaimalai D , Ragupathi N , Ranjini K , Paul H , Verghese V , et al . Ultrasound gel as a source of hospital outbreaks : Indian experience and literature review . Indian J Med Microbiol . 2019 ; 37 ( 2 ): 263-7 .
Spaulding E . Chemical disinfection and antisepsis in the hospital . Hosp Res 1957 ; 9:5-31 .
Thompson J , Garrett JH . Transducer disinfection for evaluation and insertion of peripheral and central catheters for vascular access teams and clinicians . J Vasc Access 2018 ; 23:141 – 146 .
Thorn S , Gopalasingam N , Bendtsen TF , Knudsen L , Sloth E . A technique for ultrasound-guided blood sampling from a dry and gel-free puncture area . J Vasc Access . 2016 ; 17 ( 3 ): 265-268 .
US Food and Drug Administration . Safety communication : bacteria found in other-sonic generic ultrasound transmission gel poses risk of infection . http :// dhhs . ne . gov / han % 20Documents / Advisory042012 . pdf . Accessed May 25 , 2021 .
46 june 2021 • www . healthcarehygienemagazine . com