Geistlich - Indication sheets STR-4 Soft-tissue Regeneration | Page 4

Esposito M, Grusovin MG, Polyzos IP, Felice P, Worthington HV: Timing of implant placement after tooth extraction: immediate, immediate-delayed or delayed implants? A Cochrane systematic review. Eur J Oral Implantol. 2010 Autumn;3(3):189-205. 1 Evans CD, Chen ST: Esthetic outcomes of immediate implant placements. Clin Oral Implants Res. 2008 Jan;19(1):73-80. 2 Araújo MG, Linder E, Lindhe J: Geistlich Bio-Oss ® collagen in the buccal gap at immediate implants: a 6-month study in the dog. Clin Oral Implants Res. 2011 Jan;22(1):1-8. 3 Ferrus J, Cecchinato D, Pjetursson EB, Lang NP, Sanz M, Lindhe J: Factors influencing ridge alterations following immediate implant placement into extraction sockets. Clin Oral Implants Res. 2010 Jan;21(1):22-9. 4 Canullo L, Iurlaro G, Iannello G: Double-blind randomized controlled trial study on post-extraction immediately restored implants using the switching platform concept: soft-tissue response. Preliminary report. Clin Oral Implants Res. 2009 Apr;20(4):414-25. 5 Chen ST, Buser D:Clinical and esthetic outcomes of implants placed in postextraction sites. Int J Oral Maxillofac Implants. 2009;24 Suppl:186-217. 6 Crespi R, Capparè P, Gherlone E: A 4-year evaluation of the peri-implant parameters of immediately loaded implants placed in fresh extraction sockets. J Periodontol. 2010 Nov;81(11):1629-34. 7 Januário AL, Duarte WR, Barriviera M, Mesti JC, Araújo MG, Lindhe J: Dimension of the facial bone wall in the anterior maxilla: a cone-beam computed tomography study. Clin Oral Implants Res. 2011 Feb;15 (10)1600-501. 8 Reinhardt S: Immediate implants with a simultaneous soft-tissue graft - 2 years results of a new technique. Z Zahnärztl Impl 2012, 28 (3) S. 240-247. 9 Raetzke, P. B.: Covering localized areas of root exposure employing the “envelope” technique. J Periodontol 56, 397-402 (1985). 10 Suppliers > Suture material: Terylene 4/0 Serag Wiessner > Local anesthetic: Artican-hidrochloride with adrenaline 1/100,000 > Biomaterial: Geistlich Mucograft ® , Geistlich Biomaterials > Biomaterial: Geistlich Bio-Oss ® , Geistlich Biomaterials > Implant: NobelActive NobelBiocare > Instruments: Tissue-Control Set Meisinger Contact > Dr. Stefan Reinhardt, Germany telephone: +49.251.55155, fax: +49.251.518945, e-mail: [email protected], website: www.implantatzentrum.de Further Indication Sheets > For free delivery please contact: www.geistlich.com/indicationsheets > If you no longer wish to collect Indication Sheets, please unsubscribe with your local distribution partner Geistlich Pharma AG Business Unit Biomaterials CH-6110 Wolhusen phone +41 41 492 56 30 fax +41 41 492 56 39 www.geistlich-pharma.com © 4 Literature references