Gauteng Smallholder July 2015 | Page 21

ENERGY From page 18 connecting of the system, from a dealer specialising in large off grid farm and housing systems. It is a 48V system, with locally manufactured components, except for panels (although panels are also now manufactured in South Africa), comprising the following: K 12 x 250W polycrystalline solar panels (which give 12 x 250 = 3kW), in four clusters of three panels (750W) connected in series, with each cluster's cabling going to A bank of 24 locomotive batteries delivers 48V DC to an inverter which converts the current to 220V AC in the house believes he should have forked out an additional R10 000 on a 3-phase inverter, especially if he the maximum power point about R3 000 each, comwishes to run heavy equiptracking charge controller pared to a solar 12V 105Ah ment in his workshop, or a (MPPT). cell at R1 500 to R2 800 three-phase pump, for K A 60A MPPT charge each. example. controller, (which Smit The lifetime of the 2V cells is And, in future he would like believes is a bit small for the expected to be ten to 15 to purchase an extra bank of system, pointing out that a years with that of a 12V cell batteries which will allow for 3kW system, on 48, will give only two to three years. The more optimal use at night. one 62,5A. downside, says Stephen, “is Smit points out that an extra K Storage is by 24 x 2V milthat the whole battery pack bank of batteries will expand 19, 650 Ah Benoni-made has to be replaced at the end the life of batteries. “It does locomotive batteries, joined in of its lifetime, so one should not give you more total power series for 48 volts. budget for it.” … all it means is that your K These in turn feed a 10kW As a rule, says Stephen, “if the back-up is bigger. Your total pure sinewave inverter. batteries are 100Ah you need panel output is what you Apart from the imported a solar panel larger than have available. If you use panels, the fact that these 100W. Given that the 2V cells more than this, your batteries items are locally manufacare 650Ah units, using three will be depleted”. tured, Stephen hopes that solar panels in series gives For the system installed by service levels will be high, 750W.” Stephen is capable of commenting, “You don't get “And, the good news is that handling the extra set of the same service on cheaper solar systems are covered batteries without changes, or imported Chinese products under my building insurance even two sets for that matter, that have to be replaced.” policy.” the theory being that the The 2V cells cost Stephen In retrospect, Stephen Continued on page 22 20 www.sasmallholder.co.za