T: +44(0)1443 772500
E: [email protected]
Compressed Air Quality Matters To You Make Compressed Air Quality Measurement
So Much Easier
But does it matter as much to those that have to measure it? Faster measurements allow you to get more tests done
How Does Your Compressed
Air Purity Monitoring
Procedure Measure Up?
Dew Point - Particle Concentration - Residual Oil Vapour
Handheld S505 Pressure Dew Point Sensor
Ideal for verifying desiccant or refrigerant
dryer performance anywhere. No waiting for
the sensor to react through the innovative
park festure that keeps the sensor dry
between tests.
C
M
For many companies, in-house between them or indicate inert or verification of compressed air quality viable microbiologicals, having a sensor CM
Compressed air quality audits are rarely supplements their external ISO permanently measuring at critical points MY
carried out in strict compliance with ISO 8573 audits to give a more complete in the system will give rapid indication 8573 and a lot can happen in between understanding of delivered air quality. of increased levels that would prompt
Are Regular ISO 8573 Audits Sufficient?
air quality
out their
in strict
compliance with further
ISO 8573
and a lot can happen in
investigation.
This carried
reinforces
site quality
them Compressed
that can seriously
affect audits
your are rarely
between
them that can
seriously affect
your reputation
profitability.
standards
by providing and
more
frequent For many companies, in-house
reputation
and profitability.
Whether
Y
CY
CMY
K
Portable S600 Compressed Air Purity Analyser
Measure Dew Point, Particle Concentration and
Residual Oil Vapour with one easily portable
instrument. Produce reports directly for each
test point and move to the next.
verification of compressed air quality supplements their external ISO 8573 audits to give a more regular
Removing the need for sending oil
measurement points,highlighting trends
understanding of delivered air quality.
strict compliance is important for you
is more a consideration of maintaining
that may indicate the need for planning
samples away for laboratory analysis
the
of modern
PID
remedial
action
before contamination
your site
quality standards
and sending
the air samples
Removing
the need for
away
for laboratory
analysis through through
the use
of use
modern
sensors,
a quick
assessment
of quality
and
an almost
instant response to changes.
all a quick, accurate and
sensors, Not
provides
levels
become
problematic.
purity provides
records need
to reflect
the actual
repeatable assessment of oil vapour
system conditions. The methods used in
the audits for measuring each impurity Water will condense or evaporate with an almost instant indication of
type, the length of sample times and according to temperature and pressure system changes. They also offer online
the conclusions drawn from the results changes throughout the air distribution 24/7 monitoring with alarm outputs.
must be appropriate and repeatable but system and relying on the dew point are enough questions asked about the readings from the sensor on the dryer Would you rather know beforehand or is
sufficient certainty all across the site. until the next 6 monthly audit?
Dew Point - Particle Concentration
- Residual Oil Vapour
it safe to assume everything will be fine
in the plant room, is not likely to provide
methods before the audit?
There have been occasions where Standalone dew point sensors with the test results were genuine but at a integral displays and alarm relay outputs Red Dragon Ltd t/a Measure Monitor
lower purity class than expected and are a very inexpensive way of providing Control
contractors have been told to re-test point of use verification that the Unit 15 Abergorki Industrial Estate
by a manager in denial. If your auditor delivered air is dry within the expected Ynyswen Road
knows that you expect an air purity limits. Treorchy
Designed for 24/7 continuous monitoring of Dew
Point, Particle Concentration and Residual Oil Vapour.
Communicates with plant SCADA systems through
Ethernet or RS-485 and has an integral data logger
for record security.
See us at Air-Tech Exhibition stand AF104
21-23 April 2020 NEC Birmingham
CF42 6DL
result of 1:2:1, are you certain they
couldn’t skew the results to meet this Organic and inorganic particulates can 01443 772500
in order to get paid and move on to the be measured with laser particle counters [email protected]
next job? and while they won’t differentiate www.measuremonitorcontrol.com
18 FDPP - www.fdpp.co.uk
Wall Mounted S601 Compressed Air Purity Analyser
Red Dragon Ltd t/a Measure Monitor Control
Unit 15 Abergorki Industrial Estate, Ynyswen Road, Treorchy, CF42 6DL