Hilti. Outperform. Outlast. Highlights of the IFC Guidelines for Evaluating Engineering Judgments Key Fundamental Guidelines • Use tested systems in lieu of EJs when available • Issued only by qualified technical personnel • Based upon interpolations of previously tested firestop systems and are referenced on the form • Based on the expectation that the recommended firestop system will perform as designed if subjected to the appropriate firestop test standard for the required fire-rated time period • Limited only to the specific conditions upon which it was rendered • Issued for a single job and are not transferable to another job without review by the entity who issued the EJ of all aspects of that job’s specifications to determine whether or not the EJs are applicable to the new project • Issued only in those locales where local code enforcement jurisdictions permit their use as suitable for meeting building code requirements Basic EJ Presentation Requirements • Present in descriptive formal written form with or without detail drawings • Indicate clearly that the recommended firestop system is an Engineering Judgement and NOT a listed system • Identify job, contractor, non-standard conditions and required hourly rating • Provide complete descriptions of all vital elements of the firestop system (i.e. type of assembly being penetrated, type of penetrant, size of opening, annular space requirements, etc.) • Include clear installation instructions for the firestop system • Show dates of issue and authorization signatures as well as issuer’s name, address and telephone number • Reference the number of the tested system(s) the design is based on Hilti. Outperform. Outlast. Hilti, Inc. (U.S.) 1-800-879-8000 www.us.hilti.com • Hilti (Canada) Corp. 1-800-363-4458 www.hilti.ca Three steps to requesting an Engineering Judgment 1. Gather all required project and application information. 2. Download an Engineering Judgment Request Form at www.us.hilti.com/ engineering-judgments or www.hilti.ca/ engineering-judgments. Fill out the required fields marked with an asterisk (*). Accurate information helps expedite your request. 3. Email the completed form to: usfirestopeng@ us.hilti.com. Please also include a sketch of your firestop application along with your Engineering Judgment Request Form. A member of our Firestop Team will be in touch regarding your EJ request. Hilti Firestop Saving lives through innovation and education 2