Joints |
CLICK CATEGORY INFO BELOW : |
|||
Penetrating Item ( s ) F-Rating T-Rating L-Rating Product |
System Number [ Similar FM Approved System ] |
Blank Openings
Metallic Penetrants
|
||
|
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
|
PERIMETER FIRE BARRIER JOINTS ( CURTAIN WALL ) — ASTM E2307 ( CONTINUED )
Steel Back Pan w / Glass Spandrel with Aluminum Framing ( No Back Pan Stiffener ) ( Max JW = 4 ”) ( 12.5 % vertical and horizontal movement )
Glass Spandrel Panel with Aluminum Framing Spandrel Insulation ( 6.25 % vertical and horizontal movement ) ( Max JW = 6 ”)
Galvanized Sheet Metal Pan w / Glass Spandrel with Aluminum Framing Insulation below ( Max JW = 4 ”) ( 12.5 % vertical and horizontal movement )
Galvanized Sheet Metal Pan w / Glass Spandrel with Aluminum Framing Insulation below ( Specified Thermafiber ) ( Max JW = 4 ”) ( 12.5 % vertical and horizontal movement )
Galvanized Sheet Metal Pan w / Glass Spandrel with Aluminum Framing ( Specified Thermafiber ) ( Max JW = 4 ”) ( 12.5 % vertical and horizontal movement )
Glass Spandrel Panel with Aluminum Framing Spandrel Insulation ( Max JW = 4 ”)
Glass Spandrel Panel with Aluminum Framing Spandrel Insulation ( -8 % vertical movement ) ( Max JW = 5 ”)
Glass Spandrel Panel with Aluminum Framing Spandrel Insulation ( -8 % vertical movement 11 % horizontal movement ) ( Max JW = 4.5 ”)
Glass Spandrel Panel with Aluminum Framing Steel back pan ( -8 % vertical movement 11 % horizontal movement ) ( Max JW = 4.5 ”)
Glass Spandrel Panel with Aluminum Framing Steel back pan ( -8 % vertical movement ) ( Max JW = 5 ”)
Glass Spandrel Panel with Aluminum Framing Steel back pan ( -7.5 % vertical movement ) ( Max JW = 5 ”)
Glass Spandrel Panel with Aluminum Framing Steel back pan ( -8 % vertical movement 11 % horizontal movement ) ( Max JW = 4.5 ”)
Tilt-Up Concrete Panel Curtain Wall ( Max JW = 3 ”)
Tilt-Up Concrete Panel Curtain Wall ( Max JW = 3 ”)
Galvanized Sheet Metal Pan w / Glass Spandrel with Aluminum Framing ( 100 % vision glass ) ( Max JW = 4 ”)
Glass Spandrel Panel with Aluminum Framing Steel shadow box ( Max JW = 3 ”)
Glass Spandrel Panel with Aluminum Framing Steel shadow box ( Max JW = 3 ”)
Tilt-Up Concrete Panel Curtain Wall ( Max JW = 3-1 / 4 ”)
Glass Spandrel Panel with Aluminum Framing ( Max JW = 2 ”) ( 25 % vertical movement )
Glass Spandrel Panel with Aluminum Framing ( Max JW = 6 ”)
2 Hr 1 Hr ◼
2 Hr 1 Hr
2 Hr 45 Min ◼
2 Hr 45 Min ◼
2 Hr 45 Min ◼
2 Hr 1 Hr ◼
CFS-SP WB CFS-SP SIL
CFS-SP WB CFS-SP SIL
CFS-SP WB CFS-SP SIL
CFS-SP WB CFS-SP SIL
CFS-SP WB CFS-SP SIL
CFS-SP WB CFS-SP SIL
HI / BPF 120-12
HI / BPF 120-13
HI / BPF 120-14
HI / BPF 120-15
HI / BPF 120-16
HI / BPF 120-17
2 Hr 33 Min ◼ CFS-EOS QS HI / BPF 120-18
2 Hr 33 Min ◼ CFS-EOS QS HI / BPF 120-19
2 Hr 77 Min ◼ CFS-EOS QS HI / BPF 120-20
2 Hr 77 Min ◼ CFS-EOS QS HI / BPF 120-21
2 Hr 52 Min ◼ CFS-EOS QS HI / BPF 120-22
2 Hr 52 Min ◼ CFS-EOS QS HI / BPF 120-23
2 Hr 112 Min ◼ CFS-EOS QS HI / BPF 120-24
2 Hr 2 Hr ◼ CFS-EOS QS HI / BPF 120-25
2 Hr 43 Min ◼ CFS-EOS QS HI / BPF 120-27
2 Hr 86 Min ◼
2 Hr 86 Min ◼
4 Hr 4 Hr ◼
2 Hr 1-1 / 2 Hr
2 Hr 2 Hr ◼
CFS-SP WB CFS-SP SIL
CFS-SP WB CFS-SP SIL
CFS-SP WB CFS-SP SIL
CFS-SP WB CFS-SP SIL
CFS-SP WB CFS-SP SIL
HI / BPF 120-28
HI / BPF 120-29
HI / BPF 240-01
HI / JS 120-04
HI / JS 120-05
|
Non-Metallic Pipes *
Cables / Cable Trays
Insulated Pipes
Miscellaneous Electrical ( Busway )
Miscellaneous Mechanical / Ducts
Mixed Penetrating Items *
Blank Openings
Metallic Penetrants
Non-Metallic Pipes *
Cables
Cable Trays
Insulated Pipes
Miscellaneus Electrical ( Busway )
Miscellaneous Mecahnical / Ducts *
Mixed Penetrating Items *
Blank Openings
Metallic Penetrations
Non-Metallic Pipes *
Cables
Insulated Pipes
Miscellaneous Mechanical / Duct Penetrations
Mixed Penetrating Items *
Metallic Penetrations
Non-Metallic Pipes *
Cables
Insulated Pipes
Miscellaneous Mechanical / Duct Penetrations
Mixed Penetrating Items *
Bottom of Wall ( BW-S Series )
Continuity Head-of- Wall ( CJ-D Series )
Floor-to-Floor ( FF-D Series )
Floor-to-Wall ( FW-D Series )
Intertek Series ( ASTM E 1966 )
|
Steel-Framed Floors Wood-Framed Floors Framed ( Gypsum ) Walls
Concrete Floors / Walls
|
|
Head-of-Wall ( HW-D Series ) |
Joints |
|||
Head-of-Wall ( HW-S Series ) |
||||
Wall-to-Wall ( WW-D Series ) |
||||
Wall-to-Wall ( WW-S Series ) |
||||
Perimeter Fire Barrier Joints ( Curtain Wall ) – ASTM E2307 |
||||