EcoTouch® PINK® FIBERGLAS™ Insulation
with PureFiber ® Technology
Product Data Sheet
Figure 1
effective moisture/humidity
control. Repair any punctures or
tears in the facing by taping. Follow
the tape manufacturer’s
application recommendations.
1" Ventilation
Passageway
Insulation installed too close to
light fixtures may affect the
luminaire’s performance. Do not
install insulation on top of or
within 3" of recessed light fixtures
unless the fixtures are approved
for such use. This is a requirement
of the National Electrical Code.
Due to the potential for skin
irritation, EcoTouch® Unfaced
Insulation should not be used for
exposed applications where it will
be subject to human contact.
Figure 2
Installation
Between Wood Studs/Rafters
EcoTouch® Insulation fits between
studs. If required, the flanges can
be stapled to either the face or
the side of the stud every 8–12"
to prevent gaping or
“fishmouthing” of the vapor
retarder.
EcoTouch® Unfaced insulation can
be friction-fit between studs after
the cover material has been
installed on one side of the cavity.
Use wire or metal straps to hold
insulation in place in applications
without a cover material, or
where the insulation does not fill
the depth of the cavity.
Cathedral ceiling products
(R3OC and R38C) are intended
to be friction-fit between rafters.
Cathedral ceiling insulation should
be installed to provide a minimum
1" ventilation passageway between
the roof deck and insulation. (See
Figure 1) It is recommended to
use a vent baffle to assure proper
clearance.
Between Metal Studs
EcoTouch® Insulation can be
friction-fit in place until the
interior finish is applied. Insulation
should fill the cavity and the wall
should eventually be closed on
both sides. (See Figure 2)
In areas where it will be applied
in heights over 8', use wire or
metal straps to hold the product
in place until the interior finish is
applied. When faced insulation is
used, the attachment flanges may
be taped to the face of the metal
stud prior to applying the interior
finish. Wire or metal straps
should also be used to hold the
product in place in applications
without a cover material or
where the stud depth is larger
than the insulation thickness.
Furring Strips
EcoTouch® Insulation can be
applied between furring strips, hat
channels, or Z-shaped furring in
areas where a finish surface will
be installed. Contact the furring
strip manufacturer for
appropriate fastening system.
Caution: FIBERGLAS™ insulation
may cause temporary irritation
to the skin, eyes and respiratory
tract. Avoid contact with eyes
and skin, wear loose-fitting,
long-sleeved clothing, gloves and
eye protection when handling
and applying the material. Wash
with soap and warm water after
handling. Wash work clothes
separately and wipe out washer.