QuietZone®
QuietZone®
Acoustic Floor Mat
Acoustic Floor Mat
Installation Instructions
concrete material per
manufacturer’s instructions on
top of the QuietZone Acoustic
Floor Mat so there is a layer of
gypsum concrete at least 1½”
thick covering the entire floor
surface area.
3. 1” Alternative to Gypsum
Concrete Using USG
LEVELROCK® Brand Floor
Underlayment 2500 or 3500
• Apply USG LEVELROCK®
Brand Floor Primer or
equivalent over QuietZone
Acoustic Floor Mat following
manufacturers instructions for
mixing and application.
• Pour USG LEVELROCK® Brand
Floor Underlayment 2500
or 3500 over floor primer
to a minimum thickness of
1”. Follow manufacturer’s
instructions for mixing and
application.
• Depending on the finish
floor application, apply
LEVELROCK™ Brand Surface
Enhancer SE-100 over the
USG LEVELROCK® gypsum
concrete topping. Follow
manufacturer’s instructions to
determine when and how to
apply.
• For a tile finish floor add:
Noble Company, NobleBond
21 Adhesive following
manufacturers instructions
Noble Company, NobleBond
CIS Crack Suppression
Membrane following
manufacturer’s instructions
4. Clean-up
• Remove tape from wall.
Installation Instructions
For more information, call
1-800-GET-PINK™ or visit our
Web site at: www.quietzone.com
Typical Physical Properties
Property
Test Method
Compressive Strength, Vertical Direction
ASTM D 3575 93 Suffi x D @ 25%/50%
Value
720/1800 (psf )
19% (81% Recovery)
• Trim away excess QuietZone
acoustic floor mat so that
the mat is flush with the
finished floor.
Compression Set
(50% deflection requires a loading of 1800 psf )
ASTM D 3575 93 Suffi x B
Nominal Density
ASTM C 303
2.2 (pcf )
Water Absorption
ASTM D 3575 93 Suffi x L
<0.1 (psf )
Thermal Resistance R-Value
ASTM C 518 85
1.3 (Hr•Ft. 2•°F/BTU)
• Add baseboard or finishing
trim as required.
Surface Burning Charateristics
Flame Spread
Smoke Developed
ASTM E 841
Design Considerations
QuietZone Acoustic Floor Mat is
to be placed between the
subfloor and plywood or gypsum
concrete overlayment to create
an isolation layer for sound
vibrations and impact noises such
as foot traffic. The plywood or
gypsum concrete overlayment,
once installed, “floats” on top of
the floor mat providing a rigid
surface for the finished flooring.
Fire Safety & Applicable
Standards
QuietZone Acoustic Floor Mat has
been tested in accordance with
ASTM E-84 with resulting flame
spread/smoke developed indices
of 20/50. Thermal barrie