QuietZone®
Acoustic Batts
Product Data Sheet
Single Wood Stud Wall System
STC
STC
Test No.
Fire
Rating
Fire
Test
36
OCF423
Single wood studs 16" o.c.; single layer 5/8" type "x" gypsum drywall each side;
one thickness, 3½" thick QuietZone Acoustic Batts
1 Hr.
UL U305
39
W2069
Single wood studs 16" o.c.; single layer ½" type "x" gypsum drywall each side;
one thickness, 3½" thick QuietZone Acoustic Batts
N.A.
—
40
W2469
Single wood studs 16" o.c.; double layer ½" type "x" gypsum drywall one side,
single layer other side; one thickness, 3½" thick QuietZone Acoustic Batts
N.A.
—
45
W2569
Single wood studs 16" o.c.; double layer ½" type "x" gypsum drywall each side;
one thickness, 3½" thick QuietZone Acoustic Batts
1 Hr.1
UL U305
Construction Description
1
Rating is estimated from tests using thinner assemblies of fewer layers of gypsum drywall. Specific test references are available and will be provided upon request.
Single Wood Stud with Resilient Channel Wall System
STC
STC
Test No.
Fire
Rating
Fire
Test
46
W0769
Single wood studs, resilient channel; single layer ½" type "x" gypsum drywall each side;
one thickness. 3½" thick QuietZone Acoustic Batts
N.A.
—
50
WP32302
Single wood studs, resilient channel; single layer 5/8" type "x" gypsum drywall each side;
one thickness, 3½" thick QuietZone Acoustic Batts
1 Hr.
OSU T-3127
52
W0669
Single wood studs, resilient channel; single layer ½" type "x" gypsum drywall one side,
double layer other side; one thickness, 3½" thick QuietZone Acoustic Batts
N.A.
—
56
W0569
Single wood studs, resilient channel; double layer ½" type "x" gypsum drywall each side;
one thickness, 3½" thick QuietZone Acoustic Batts
1 Hr.1
OSU T-3127
Construction Description
1
Rating is estimated from tests using thinner assemblies of fewer layers of gypsum drywall. Specific test references are available and will be provided upon request.
Listed in the Gyspum Association Fire Resistance Design Manual
2
Staggered Wood Stud Wall System
STC
STC
Test No.
Fire
Rating
Fire
Test
46
W5769
Staggered wood studs 16" o.c.; single layer 5/8" type "x" gypsum drywall each side;
one thickness, 3½" thick QuietZone Acoustic Batts
1 hr.1
UL U305
51
W01486
Staggered wood studs 16" o.c.; single layer ½" type "x" gypsum drywall each side;
one thickness, 3½" thick QuietZone Acoustic Batts
N.A.
—
51
OC5FC
Staggered wood studs 16" o.c.; single layer ½" type "x" gypsum drywall each side;
two thicknesses, 3½" thick QuietZone Acoustic Batts
1 hr.
OSU 4970
53
W4769
Staggered wood studs 24" o.c.; double layer ½" type "x" gypsum drywall one side,
single layer other side; one thickness, 3½" thick QuietZone Acoustic Batts
N.A.
—
55
W4869
Staggered wood studs 24" o.c.; double layer ½" type "x" gypsum drywall each side;
one thickness, 3½" thick QuietZone Acoustic Batts
1 hr.1
UL U309
Construction Description
1
Rating is estimated from tests using thinner assemblies of fewer layers of gypsum drywall. Specific test references are available and will be provided upon request.
QuietZone Wall Framing System
STC
STC
Test No.
Fire
Rating
Fire
Test
57
E90-99087
2x4 QuietZone Acoustic Framing on 16” centers, double layers ½” type "x" gypsum
drywall each side, 3½" thick QuietZone Acoustic Batts
1 hr.1
UL U305
60
E90-01029
2x6 QuietZone Acoustic Framing on 16” centers, double layers 5/8" type "x" gypsum
drywall each side; 5½" thick QuietZone Acoustic Batts
N.A.
—
63
E90-99102
2x6 QuietZone Acoustic Framing on 24” centers, double layers 5/8" type "x" gypsum
drywall each side; 5½" thick QuietZone Acoustic Batts
1 hr.
OSU 4970
Construction Description