QuietZone®
Acoustic Batts
Product Data Sheet
Product Installation
QuietZone® acoustic batts are
designed for interior cavities only
and are not recommended for
exterior walls. The facing on this
product is provided for ease of
installation and is not a vapor
retarder.
• Insulation must fit snugly
into place, filling the cavity
completely.
• Staple batts along kraft flanges
to the inside of the wall
framing.
• In cases where wall
penetrations apply, cut with a
utility knife to fit around wiring,
outlets, junction boxes, pipes
and other obstructions.
• For desired performance,
keep batts dry during shipping,
storage and installation.
• QuietZone® acoustic batts
may be installed with the
facing toward either side of
interior walls, floors, or ceilings
in conventional wood stud
construction.
• QuietZone® acoustic batts (15"
or 23" width) will be required
in the cavity space between
wall framing sections spaced
either 16" or 24" o.c.
• Owens Corning acoustic
batts will be required to fill
the cavity space between wall
framing sections spaced either
16" or 24" o.c. when using 2x6
QuietZone® acoustic wall
framing.
*The facing on QuietZone ® batts will burn and must
not be left exposed. The facing must be installed in
substantial contact with an approved interior material.
Protect facing from any open flame or heat surface.
Durable Composition
QuietZone® acoustic batts:
Figure 1
Single wood studs, QuietZone ® acoustic batt insulation and a
single layer of ½" Type X gypsum board.
• Are dimensionally stable
• Will not slump over time
• Are composed of inorganic
glass fibers which do not
absorb water
Zo
iet
Qu
• Maintain original acoustic
properties over time
ne
Zo
iet
Qu
ne
• Will not rot or mildew
Fire Safety
When installing QuietZone®
acoustic batts in areas containing
high temperature appliances,
fireplace flues or furnaces, the
kraft-facing must be protected
and enclosed with an approved
finishing material.*
Applicable Standards
Kraft facing will burn. Do not
leave exposed. Facing must be
installed in substantial contact
with an approved ceiling, floor
or wall material. Keep open
flame and other heat sources
away from facing. Do not place
insulation within 3" of light
fixtures or similar electrical
devices unless device is labeled
for contact with insulation. Use
only unfaced insulation between
wood framing and masonry
chimneys. Do not use insulation
in spaces around metal chimneys,
fireplaces, or flues. See package
ne
Zo
iet
Qu
for warnings fire hazard and
installation instructions, or call
1-419-248-8234.
Always check with your local
building code official regarding
local requirements affecting
installation of all building
components.