Product Data Sheet
EUROSPAN®
ACOUSTICAL CEILING SYSTEM
PART 1 GENERAL
2.5
Acoustical Performance – in accordance with ASTM C
423 (Type E 400 Mounting) components shall have a
minimum NRC of: 1.00 (1 1/2” thick).In accordance with
ASTM C 423 (Type A Mounting) components shall have a
minimum NRC of: .80 (1 1/2” thick) and .95 (2 1/2” thick).
Flammability – All system components shall meet a 25/50
Class A rating in accordance with ASTM E 84.
1.1
Work in this section shall be subject to drawings, general
conditions, schedules, addenda and other contract
documents.
1.2
The extent of the system is shown on the drawings and in
the schedules.
2.6
1.3
Submit ________ samples of each type of system as
shown on the drawings and in schedules and include
appropriate technical information including test data
and maintenance instructions. Submit ________ fabric
selector cards from manufacturer’s standard or custom
finishes.
PART 3 EXECUTION
1.4
Installation of components shall not begin until all wet
work (plastering, concrete, etc.) is completed and dry.
The panels are designed for installation under standard
occupancy conditions from 60°F to 85°F and not more
than 80% relative humidity (RH) in an enclosed building.
Manufacturer’s Instructions – Comply with the instructions
and recommendations of the Eurospan Acoustical Ceiling
System manufacturer.
3.2
Examination – Verify that site conditions are acceptable
for installation of the Eurospan Acoustical Ceiling System.
Do not proceed with installation of the Eurospan
Acoustical Ceiling System until unacceptable conditions
are corrected.
3.3
Installation – Review shop drawings and determine
location of hardware. Identify components and verify
quantities. Install Eurospan Acoustical Ceiling System in
accordance with manufacturers guidelines.
3.4
Demonstration – Demonstrate proper use, function
and maintenance of Eurospan Acoustical Ceiling System
components to Owner’s personnel.
3.5
Protection – Protect installed work from damage due to
subsequent construction activity on the site.
Components shall be installed according to manufacturer’s
recommendations and instructions.
1.5
3.1
1.6
The contractor shall be responsible for the examination
and acceptance of all surfaces and conditions prior to the
system installation, and will furnish all necessary hardware
and accessories for the complete job installation.
1.7
Substitutions or changes will only be permitted by prior
approval by the architect.
PART 2 MATERIALS
Thank you for choosing Eurospan® for your acoustical needs.
2.1
Eurospan Acoustical Ceiling System shall have a 10-year
manufacturer’s warranty.
The information provided above is correct to the best of our
knowledge at time of printing. We reserve the right to make
changes without prior notification.
2.2
Acoustical core shall be constructed of a composite core
construction of 1” thick, medium density glass fiber core
with 12 mil thick face sheet of white/translucent glass
mat thermally bonded to the base core finish surface.
Other glass fiber cores of 1/2”, 3/4”, 1”, 1 1/2”, 2”, 3”, and
4” thickness; with various densities are available to meet
specific acoustical requirements.
2.3
Product finish shall be standard white (or specify custom
color)______________.
2.4
Mounting shall be square perimeter track and square fine
line or reveal mid joint track.
DISCLAIMER OF LIABILITY
Technical information contained herein is furnished without charge or obligation and is
given and accepted at recipient’s sole risk. Because conditions of use may vary and are
beyond our control, Owens Corning makes no representation about, and is not responsible
or liable for the accuracy or reliability of data associated with particular uses of any product
described herein. Nothing contained in this bulletin shall be considered a recommendation.
+YWXEJWSR 6SEH
0EH]WQMXL;MWGSRWMR
T: 1-800-932-2383
F: 1-800-833-4798
www.conweddesignscape.com
4YF2S&4VMRXIH MR 97%%TVMP
3[IRW 'SVRMRK%PP 6MKLXW 6IWIVZIH
0))( MW E VIKMWXIVIH XVEHIQEVO SJ 97+VIIR &YMPHMRK 'SYRGMP