INSTALLATION INSTRUCTIONS
ACCESS CEILING SYSTEM
8. Panels must be aligned one-at-a-time as installed. Usually,
aligning Saddle Clips or Spring Retainer Clips to ensure
springs are in the right place and vertical will resolve
alignment issues. Attempting to install all panels and then
aligning as a second step will result in failure!!!
Torsion Springs must
be vertical and panel
in proper alignment
before installing the
next panel!
Penetrations
• Penetrations are handled similar to most drop-ceiling
applications. Use escutcheon plates where appropriate for
penetrations.
Removal
• Avoid cutting near panel frames. 3” minimum is
recommended.
• Independently support all suspended items including
sprinklers, lights, diffusers and etceteras.
Cleaning Guidelines
For fabric and painted finishes, general maintenance for dust
removal is light brushing or vacuuming. Fingerprints and light
soiling can often be removed using a dry chemical sponge or an
art gum eraser. For more vigorous treatments on fabric covered
panels, the fabric manufacturer should be consulted. Most
polyester fabrics clean well by sponging with the foam from a
mild detergent or upholstery shampoo, followed by rinsing with
a clean sponge. Other cleaning agents, including solvent-based
cleaners can be used to remove spotting, however always pretest in an unseen area.