Product Data Sheet
URBAN FOREST PANELS
PART 1 GENERAL
1.1 Work in this section shall be subject to drawings, general
conditions, schedules, addenda and other contract
documents.
1.2 The extent of the acoustical panels is shown on the
drawings and in the schedules.
1.3 Submit _______ (select quantity) samples of each type of
acoustical panel as shown on the drawings and in schedules
and include appropriate technical information including test
data and maintenance instructions. Submit __________
(select quantity) fabric selector cards from manufacturer’s
standard finishes, or designer specified finishes.
1.4 Acoustical panels shall be installed according to
manufacturer’s recommendations and instructions.
1.5 Installation of acoustical panels shall not begin until all wet
work (plastering, concrete, etc.) is completed and dry.
Building shall be properly enclosed and under standard
occupancy conditions (temperature of 60-85° F and not
more than 70% relative humidity) before installation begins.
Edge treatment shall be resin hardened beneath heatformed co-polymer.
2.5 Panel finish shall be Riga Birch, Honey Maple, Pearwood,
Wild Apple, Spiced Fruitwood, Black Cherry or custom
____________________ (specify color). Co-polymer shall
be applied directly to face and edges of the panel.
2.6 Mounting shall be: Adhesive/Resin, Impaling/Adhesive,
Lay-in, Magnet, VELCRO®, Panel Clip to Z-Bar, Panel Clip
to Double Wall Clip, Z-Bar to Z-Bar (recommended
for ceilings), Aluminum Z-Clips, Panel Clips/VELCRO®
or custom ________________ (specify). Adhesive,
miscellaneous fasteners, (i.e. nails, screws, etc.) and standard
continuous wall leveling angle are to be supplied by the
contractor.
2.7 Acoustical Performance – panels shall have a minimum
NRC of _____ (please specify).
2.8 Flammability – All panel components shall have a Class “A”
fire rating in accordance with ASTM E-84.
2.9 R-Value is _____. (Calculated using the R-factor of 4.16
per inch of thickness.)
1.6 The contractor shall be responsible for the examination
and acceptance of all surfaces and conditions prior to the
acoustical panel installation.
Thank you for choosing Conwed Designscape|Wall
Technology for your acoustical needs.
1.7 Substitutions or changes will only be permitted by prior
approval by the architect.
The information provided above is correct to the best of our
knowledge at time of printing. We reserve the right to make
changes without prior notification.
PART 2 MATERIALS
DISCLAIMER OF LIABILITY
Technical information contained herein is furnished without charge or obligation and is
given and accepted at recipient’s sole risk. Because conditions of use may vary and are
beyond our control, Owens Corning makes no representation about, and is not responsible
or liable for the accuracy or reliability of data associa FVBv