Product Data Sheet
SKYWAY™ CEILING CLOUDS
TYPE II
PART 1 GENERAL
1.1 Work in this section shall be subject to drawings, general
conditions, schedules, addenda and other contract
documents.
2.3 Sizes: ____ width and _____high or as shown on drawings.
Standard maximum is 48” x 120”. Custom sizes are
available. Panels are to be manufactured according to field
dimensions supplied by the installing contractor. Standard
tolerances are ± 1/16” in width and length.
1.2 The extent of the acoustical panels is shown on the
drawings and in the schedules.
2.4 Edge profile shall be square or custom__________
(specify). Corner detail shall be Square or radius.
1.3 Submit _______ (select quantity) samples of each type
of acoustical panel as shown on the drawings and in
schedules and include appropriate technical information
including test data and maintenance instructions. Submit
__________ (select quantity) fabric selector cards from
manufacturer’s standard finishes, or designer specified
finish.
2.5 Panel finish shall be ___________________________
______________ (specify finish manufacture, pattern
color and specifier). Finish shall be applied directly over
the face and edges and returned to the back to provide
a full finished edge. All corners are fully tailored. Optional
backing includes fabric or scrim (specify).
1.4 Acoustical panels shall be installed according to
manufacturer’s recommendations and instructions.
1.5 Installation of acoustical panels shall not begin until all wet
work (plastering, concrete, etc.) is completed and dry.
Building shall be properly enclosed and under standard
occupancy conditions (temperature of 60-85° F and not
more than 70% relative humidity) before installation begins.
2.6 Standard mountings shall be resin spots for either field
applied self-drilling acoustical anchors or ceiling grid
mains (by others). Both are attached via wire or cable (by
others). (Please specify).
2.7 Acoustical Performance: panels shall have a minimum NRC
of_____(please specify) in accordance with ASTM C-423.
2.8 Flammability: All panel components shall have a Class “A:
fire rating in accordance with ASTM E-84.
1.6 The contractor shall be responsible for the examination
and acceptance of all surfaces and conditions prior to the
acoustical panel installation.
Thank you for choosing Conwed Designscape|Wall
Technology for your acoustical needs.
1.7 Substitutions or changes will only be permitted by prior
approval by the architect.
The information provided above is correct to the best of our
knowledge at time of printing. We reserve the right to make
changes without prior notification.
PART 2 MATERIALS
DISCLAIMER OF LIABILITY
Technical information contained herein is furnished without charge or obligation and
is given and accepted at recipient’s sole risk. Because conditions of use may vary and
are beyond our control, Owens Corning makes no representation about, and is not
responsible or liable for the accuracy or reliability of data associated with particular uses
of any product described herein. Nothing contained in this bulletin shall be considered a
recommendation.
2.1 Acoustical ceiling panels shall be: Skyway Ceiling Clouds
Type II as manufactured by Conwed Designscape|Wall
Technology, 800 Gustafson Road, Ladysmith, WI 54848.
Phone (800) 932-2383, fax (800) 833-4798.
2.2 Acoustical panels shall be constructed of a composite
core construction of dimensionally stable rigid fiberglass
of medium density laminated to 1/8” molded fiberglass on
both face and back. Absorptive thickness: shall be (choose
one) 1-1/4”, 1-3/4” or 2-1/4”.
+YWXEJWSR 6SEH
0EH]WQMXL;MWGSRWMR
T: 1-800-932-2383
F: 1-800-833-4798
www.conweddesignscape.com
4YF2S%4VMRXIH MR 97%%TVMP
3[IRW 'SVRMRK%PP 6MKLXW 6IWIVZIH
0))( MW E VIKMWXIVIH XVEHIQEVO SJ 97+VIIR &YMPHMRK 'SYRGMP