Finishes Manufacturer's Product Guide Vol. 1 | Page 170

Product Data Sheet CURVED REFLECTIVE CEILING CLOUDS PART 1 GENERAL Submit _______ (select quantity) samples of each type of acoustical panel as shown on the drawings and in schedules and include appropriate technical information including test data and maintenance instructions. Submit __________ (select quantity) fabric selector cards from manufacturer’s standard finishes, or designer specified finishes. 2.6 Standard mountings shall be direct attachment to the exposed metal frame with self-drilling acoustical hangers (supplied) or custom ________________ (specify). Adhesive and miscellaneous fasteners, (i.e. nails, screws, etc are to be supplied by the contractor. 2.7 Acoustical Performance – panels shall have a minimum NRC of _____ (please specify) in accordance with ASTM C-423 (Type “A” Mounting). 2.8 Flammability – All panel components except MDO plywood shall have a Class “A” fire rating in accordance with ASTM E-84. The extent of the acoustical panels is shown on the drawings and in the schedules. 1.3 Panel finish shall be gel-coat or ___________________ _____________________ (specify finish manufacturer, pattern, color and specifier). Finish shall be applied directly over the face and edges and returned to the back to provide a full finished edge. All corners are fully tailored. Work in this section shall be subject to drawings, general conditions, schedules, addenda and other contract documents. 1.2 Edge profile shall be: Square, radius, full bevel, halfbevel, miter, or custom __________________ (specify). Corner detail shall be: Square, radius or custom _______________ (specify). 2.5 1.1 2.4 1.4 Acoustical panels shall be installed according to manufacturer’s recommendations and instructions. 1.5 Installation of acoustical panels shall not begin until all wet work (plastering, concrete, etc.) is completed and dry. Building shall be properly enclosed and under standard occupancy conditions (temperature of 60-85°F and not more than 70% relative humidity) before installation begins. 1.6 1.7 The contractor shall be responsible for the examination and acceptance of all surfaces and conditions prior to the acoustical panel installation. Substitutions or changes will only be permitted by prior approval by the architect. PART 2 MATERIALS 2.1 Acoustical ceiling panels shall be: Curved Reflective Ceiling Clouds as manufactured by Conwed Designscape|Wall Technology, 800 Gustafson Road, Ladysmith, WI 54848. Phone (800) 932-2383, fax (800) 833-4798 2.2 Sizes: ______ width and _______ high or as shown on drawings. Standard maximum size is 48” wide x 96” high (nominal). Custom or larger sizes available; consult manufacturer. Panels are to be manufactured according to field dimensions supplied by the installing contractor. Standard tolerances are ± 1/16” in width and length. The information provided above is correct to the best of our knowledge at time of printing. We reserve the right to make changes without prior notification. DISCLAIMER OF LIABILITY Technical information contained herein is furnished without charge or obligation and is given and accepted at recipient’s sole risk. Because conditions of use may vary and are beyond our control, Owens Corning makes no representation about, and is not responsible or liable for the accuracy or reliability of data associated with particular uses of any product described herein. Nothing contained in this bulletin shall be considered a recommendation. Acoustical Panels shall be constructed of ¾” MDO (Medium Density Overlay) plywood backed by 1” x 1” pre-curved metal ribs. 2.3 Thank you for choosing Conwed Designscape|Wall Technology for your acoustical needs.  +YWXEJWSR 6SEH 0EH]WQMXL;MWGSRWMR  T: 1-800-932-2383 F: 1-800-833-4798 www.conweddesignscape.com 4YF2S%4VMRXIH MR 97%%TVMP  Œ  3[IRW 'SVRMRK%PP 6MKLXW 6IWIVZIH 0))( MW E VIKMWXIVIH XVEHIQEVO SJ 97+VIIR &YMPHMRK 'SYRGMP