Product Data Sheet
CURVED REFLECTIVE
CEILING CLOUDS
PART 1 GENERAL
Submit _______ (select quantity) samples of each type
of acoustical panel as shown on the drawings and in
schedules and include appropriate technical information
including test data and maintenance instructions. Submit
__________ (select quantity) fabric selector cards from
manufacturer’s standard finishes, or designer specified
finishes.
2.6
Standard mountings shall be direct attachment to the
exposed metal frame with self-drilling acoustical hangers
(supplied) or custom ________________ (specify).
Adhesive and miscellaneous fasteners, (i.e. nails, screws,
etc are to be supplied by the contractor.
2.7
Acoustical Performance – panels shall have a minimum
NRC of _____ (please specify) in accordance with ASTM
C-423 (Type “A” Mounting).
2.8
Flammability – All panel components except MDO
plywood shall have a Class “A” fire rating in accordance
with ASTM E-84.
The extent of the acoustical panels is shown on the
drawings and in the schedules.
1.3
Panel finish shall be gel-coat or ___________________
_____________________ (specify finish manufacturer,
pattern, color and specifier). Finish shall be applied directly
over the face and edges and returned to the back to
provide a full finished edge. All corners are fully tailored.
Work in this section shall be subject to drawings, general
conditions, schedules, addenda and other contract
documents.
1.2
Edge profile shall be: Square, radius, full bevel, halfbevel, miter, or custom __________________ (specify).
Corner detail shall be: Square, radius or custom
_______________ (specify).
2.5
1.1
2.4
1.4
Acoustical panels shall be installed according to
manufacturer’s recommendations and instructions.
1.5
Installation of acoustical panels shall not begin until all wet
work (plastering, concrete, etc.) is completed and dry.
Building shall be properly enclosed and under standard
occupancy conditions (temperature of
60-85°F and not more than 70% relative humidity) before
installation begins.
1.6
1.7
The contractor shall be responsible for the examination
and acceptance of all surfaces and conditions prior to the
acoustical panel installation.
Substitutions or changes will only be permitted by prior
approval by the architect.
PART 2 MATERIALS
2.1
Acoustical ceiling panels shall be: Curved Reflective
Ceiling Clouds as manufactured by Conwed
Designscape|Wall Technology, 800 Gustafson Road,
Ladysmith, WI 54848. Phone (800) 932-2383, fax (800)
833-4798
2.2
Sizes: ______ width and _______ high or as shown
on drawings. Standard maximum size is 48” wide x 96”
high (nominal). Custom or larger sizes available; consult
manufacturer. Panels are to be manufactured according
to field dimensions supplied by the installing contractor.
Standard tolerances are ± 1/16” in width and length.
The information provided above is correct to the best of our
knowledge at time of printing. We reserve the right to make
changes without prior notification.
DISCLAIMER OF LIABILITY
Technical information contained herein is furnished without charge or obligation and is
given and accepted at recipient’s sole risk. Because conditions of use may vary and are
beyond our control, Owens Corning makes no representation about, and is not responsible
or liable for the accuracy or reliability of data associated with particular uses of any product
described herein. Nothing contained in this bulletin shall be considered a recommendation.
Acoustical Panels shall be constructed of ¾” MDO
(Medium Density Overlay) plywood backed by 1” x 1”
pre-curved metal ribs.
2.3
Thank you for choosing Conwed Designscape|Wall
Technology for your acoustical needs.
+YWXEJWSR 6SEH
0EH]WQMXL;MWGSRWMR
T: 1-800-932-2383
F: 1-800-833-4798
www.conweddesignscape.com
4YF2S%4VMRXIH MR 97%%TVMP
3[IRW 'SVRMRK%PP 6MKLXW 6IWIVZIH
0))( MW E VIKMWXIVIH XVEHIQEVO SJ 97+VIIR &YMPHMRK 'SYRGMP