Product Data Sheet
FOUNDATIONS CEILING PANELS
PART 1 GENERAL
1.1 Work in this section shall be subject to drawings, general
conditions, schedules, addenda and other contract
documents.
1.2 The extent of the acoustical panels is shown on the
drawings and in the schedules.
1.3 Submit _______ (select quantity) samples of each type
of acoustical panel as shown on the drawings and in
schedules and include appropriate technical information
including test data and maintenance instructions. Submit
__________ (select quantity) fabric selector cards from
manufacturer’s standard finishes, or designer specified
finishes
1.4 Acoustical panels shall be installed according to
manufacturer’s recommendations and instructions.
1.5 Installation of acoustical panels shall not begin until all wet
work (plastering, concrete, etc.) is completed and dry.
Building shall be properly enclosed and under standard
occupancy conditions (temperature of
60-85°F and not more than 70% relative humidity) before
installation begins.
1.6 The contractor shall be responsible for the examination
and acceptance of all surfaces and conditions prior to the
acoustical panel installation.
1.7 Substitutions or changes will only be permitted by prior
approval by the architect.
PART 2 MATERIALS
2.1 Foundations Acoustical Ceilings shall be: Foundations
Acoustical Ceilings as manufactured by Conwed
Designscape|Wall Technology, 800 Gustafson Road,
Ladysmith, WI 54848. Phone (800) 932-2383,
fax (800) 833-4798.
tolerances are ± 1⁄16" in width and length.
2.4 Edge profile shall be: Square, radius, full bevel, halfbevel, miter, or custom __________________
(specify). Corner detail shall be: Square or custom
_______________ (specify). Edge treatment shall be:
resin hardened, aluminum or high-pressure laminate
(with square edge only) or custom _______________
(specify).
2.5 Panel finish shall be Foundations Acoustical Ceilings
acoustically transparent finish. Finish shall be applied
directly over the face and edges of the panel to provide a
full finished edge. All corners are fully tailored.
2.6 Mounting shall be: Lay-in, Z-Bar to Z-Bar or custom
________________ (specify). Adhesive, miscellaneous
fasteners, (i.e. nails, screws, etc.) and standard continuous
wall leveling angle are to be supplied by the contractor.
2.7 Acoustical Performance – panels shall have a minimum
NRC of _____ (please specify) in accordance with ASTM
C-423 (Type “A” Mounting).
2.8 Flammability – All panel components shall have a Class
“A” fire rating in accordance with ASTM E-84.
Thank you for choosing Conwed Designscape|Wall
Technnology for your acoustical needs.
The information provided above is correct to the best of our
knowledge at time of printing. We reserve the right to make
changes without prior notification.
DISCLAIMER OF LIABILITY
Technical information contained herein is furnished without charge or obligation and
is given and accepted at recipient’s sole risk. Because conditions of use may vary and
are beyond our control, Owens Corning makes no representation about, and is not
responsible or liable for the accuracy or reliability of data associated with particular uses
of any product described herein. Nothing contained in this bulletin shall be considered
a recommendation.
2.2 Acoustical Panels shall be constructed of a composite
core construction of dimensionally stable rigid fiberglass
of 6-7 pcf density laminated to 1⁄8" 16-20 pcf molded glass
fiber. Thickness (choose one) ¾", 1", 1-½", 2", 3", 4" plus 1⁄8"
or custom ____________ (specify).
2.3 Sizes: ______ width and _______ high or as shown on
drawings. Standard maximum size is 48” wide x 120” high.
Custom or larger sizes available; consult manufacturer.
Panels are to be manufactured according to field
dimensions supplied by the installing contractor. Standard
+YWXEJWSR 6SEH
0EH]WQMXL;MWGSRWMR
T: 1-800-932-2383
F: 1-800-833-4798
www.conweddesignscape.com
4YF2S%4VMRXIH MR 97%%TVMP
3[IRW 'SVRMRK%PP 6MKLXW 6IWIVZIH
0))( MW E VIKMWXIVIH XVEHIQEVO SJ 97+VIIR &YMPHMRK 'SYRGMP