Product Data Sheet
ACCESS CEILING SYSTEM
PART 1 GENERAL
1.1 Work in this section shall be subject to drawings, general
conditions, schedules, addenda and other contract
documents.
1.2 The extent of the acoustical panels is shown on the
drawings and in the schedules.
1.3 Submit _______ (select quantity) samples of each type of
acoustical panel as shown on the drawings and in schedules
and include appropriate technical information including test
data and maintenance instructions. Submit __________
(select quantity) fabric selector cards from manufacturer’s
standard finishes, or designer specified finishes.
1.4 Acoustical panels shall be installed according to
manufacturer’s recommendations and instructions.
1.5 Installation of acoustical panels shall not begin until all wet
work (plastering, concrete, etc.) is completed and dry.
Building shall be properly enclosed and under standard
occupancy conditions (temperature of 60-85°F and not
more than 70% relative humidity) before installation begins.
1.6 The contractor shall be responsible for the examination
and acceptance of all surfaces and conditions prior to the
acoustical panel installation.
1.7 Substitutions or changes will only be permitted by prior
approval by the architect.
PART 2 MATERIALS
2.1 Acoustical ceiling panels shall be: Access Ceiling Systems
manufactured by Conwed Designscape|Wall Technology,
800 Gustafson Road, Ladysmith, WI 54848.
Phone (800) 932-2383, fax (800) 833-4798.
2.4 Edge profile shall be: Slightly beveled to create 1/8” reveal.
Flat panel can have non-metal curving edge. 3” to 6”
integral returned edges are available.
2.5 Panel finish shall be Foundations, factory painted, or
fabric ___________________________________
___(specify manufacturer, pattern, color and specifier).
Fabric shall be applied directly over the face and edges and
returned to the back to provide a full finished edge. All
corners are fully tailored.
2.6 Torsion spring mounting, grid mains and spacer bars are
provided (attached by others)). Adhesive and miscellaneous
fasteners, (i.e. nails, screws, etc are to be supplied by the
contractor.
2.7 Acoustical Performance – panels shall have a minimum
NRC of _____ (please specify) in accordance with ASTM
C-423 (Type “E-400” Mounting).
2.8 Flammability – All panel components shall have a Class “A”
fire rating in accordance with ASTM E-84.
Thank you for choosing Conwed Designscape|Wall
Technology for your acoustical needs.
The information provided above is correct to the best of our
knowledge at time of printing. We reserve the right to make
changes without prior notification.
DISCLAIMER OF LIABILITY
Technical information contained herein is furnished without charge or obligation and is given
and accepted at recipient’s sole risk. Because conditions of use may vary and are beyond our
control, Owens Corning makes no representation about, and is not responsible or liable for
the accuracy or reliability of data associated with particular uses of any product described
herein. Nothing contained in this bulletin shall be considered a recommendation.
2.2 Acoustical Panels shall be constructed of 1-1/8” thick
aluminum framed 6-7 pcf fiberglass and 16-20 pcf impact
resistant molded fiberglass.
2.3 Sizes: ______ width and _______ high or as shown
on drawings. Standard maximum size is 4’ x 12’ and 5’
x 10’ for flat panels. Custom sizes are available; consult
manufacturer. Panels are to be manufactured according
to field dimensions supplied by the installing contractor.
Standard tolerances are ±1/16” in width and length.