Product Data Sheet
RESPOND® A SERIES
A100/A200/A300/A400
PART 1 GENERAL
1.1 Work in this section shall be subject to drawings, general
conditions, schedules, addenda and other contract
documents.
1.2 The extent of the acoustical panels is shown on the
drawings and in the schedules.
1.3 Submit _______ (select quantity) samples of each type
of acoustical panel as shown on the drawings and in
schedules and include appropriate technical information
including test data and maintenance instructions. Submit
__________ (select quantity) fabric selector cards from
manufacturer’s standard finishes, or designer specified
finishes.
1.4 Acoustical panels shall be installed according to
manufacturer’s recommendations and instructions.
1.5 Installation of acoustical panels shall not begin until all wet
work (plastering, concrete, etc.) is completed and dry.
Building shall be properly enclosed and under standard
occupancy conditions (temperature of 60-85°F and not
more than 70% relative humidity) before installation
begins.
1.6 The contractor shall be responsible for the examination
and acceptance of all surfaces and conditions prior to the
acoustical panel installation.
1.7 Substitutions or changes will only be permitted by prior
approval by the architect.
PART 2 MATERIALS
2.1 Acoustical wall panels shall be: Respond® A Series
Acoustical Wall Panels as manufactured by Conwed
Designscape|Wall Technology, 800 Gustafson Road,
Ladysmith, WI 54848. Phone (800) 932-2383,
fax (800) 833-4798.
2.2 Acoustical Panels shall be constructed of a composite
core construction of dimensionally stable rigid fiberglass of
6-7 pcf density. Thickness (choose one) 1/2”, 3/4”, 1”, 1-1/2”,
2”, 3”, 4” or custom __________ (specify).
2.3 Sizes: ______ width and _______ high or as shown on
drawings. Maximum size is 4’ x 10’ for 3/4”, 1”, 1-1/2”, 2”,
3”. 4”maximum is 4’ x 6’ or 24 square feet due to weight.
Custom or larger sizes available; consult manufacturer.
Panels are to be manufactured according to field
dimensions supplied by the installing contractor. Standard
tolerances are ± 1/16” in width and length.
2.4 Edge profile shall be: Square, radius, full bevel, halfbevel, miter, or custom __________________
(specify). Corner detail shall be: Square, radius or custom
_______________________ (specify). Edge treatment
shall be: resin hardened, aluminum or high-pressure
laminate (with square edge only), wood (all profiles
available) or custom _______________ (specify).
2.5 Panel finish shall be __________________________
______________ (specify finish manufacturer, pattern,
color and specifier). Finish shall be applied directly over
the face and edges of the panel and returned to the back
of the panel to provide a full finished edge. All corners are
fully tailored.
2.6 Mounting shall be: Adhesive/Resin, Adhesive No Resin,
Impaling/Adhesive, Lay-in, Magnet, Spline, VELCRO,®
Panel Clip to Z-Bar, Panel Clip to Double Wall Clip,
Z-Bar to Z-Bar (strongly recommended for ceilings),
Aluminum Z-Clips, Panel Clips/VELCRO® or custom
________________ (specify). Leveling angles are
supplied if appropriate. Adhesive, miscellaneous fasteners,
(i.e. nails, screws, etc.) and standard continuous wall
leveling angle are to be supplied by the contractor.
2.7 Acoustical Performance – panels shall have a minimum
NRC of _____ (please specify).
2.8 Flammability – All panel components shall have a Class
“A” fire rating in accordance with ASTM E-84.
2.9 R-Value is _____. (Calculated using the R-factor of 4.16
per inch of thickness.)
Thank you for choosing Conwed Designscape|Wall
Technology for your acoustical needs.
The information provided above is correct to the best of our
knowledge at time of printing. We reserve the right to make
changes without prior notification.
DISCLAIMER OF LIABILITY
Technical information contained herein is furnished without charge or obligation and is
given and accepted at recipient’s sole risk. Because conditions of use may vary and are
beyond our control, Owens Corning makes no representation about, and is not responsible
or liable for the accuracy or reliability of data associated with particular uses of any product
described herein. Nothing contained in this bulletin shall be considered a recommendation.
+YWXEJWSR 6SEH
0EH]WQMXL;MWGSRWMR
T: 1-800-932-2383
F: 1-800-833-4798
www.conweddesignscape.com
4YF2S+4VMRXIH MR 97%%TVMP
3[IRW 'SVRMRK%PP 6MKLXW 6IWIVZIH
0))( MW E VIKMWXIVIH XVEHIQEVO SJ 97+VIIR &YMPHMRK 'SYRGMP