Product Data Sheet
REBOUND PANELS
PART 1 GENERAL
1.1 Work in this section shall be subject to drawings, general
conditions, schedules, addenda and other contract
documents.
1.2 The extent of the acoustical panels is shown on the
drawings and in the schedules.
1.3 Submit _______ (select quantity) samples of each type of
acoustical panel as shown on the drawings and in schedules
and include appropriate technical information including test
data and maintenance instructions. Submit __________
(select quantity) fabric selector cards from manufacturer’s
standard finishes, or designer specified finishes.
1.4 Acoustical panels shall be installed according to
manufacturer’s recommendations and instructions.
1.5 Installation of acoustical panels shall not begin until all wet
work (plastering, concrete, etc.) is completed and dry.
Building shall be properly enclosed and under standard
occupancy conditions (temperature of 60-85°F and not
more than 70% relative humidity) before installation begins.
1.6 The contractor shall be responsible for the examination
and acceptance of all surfaces and conditions prior to the
acoustical panel installation.
1.7 Substitutions or changes will only be permitted by prior
approval by the architect.
PART 2 MATERIALS
2.1 Acoustical panels shall be: Rebound Panels as manufactured
by Conwed Designscape|Wall Technology, 800 Gustafson
Road, Ladysmith, WI 54848. Phone (800) 932-2383,
fax (800) 833-4798.
2.2 Acoustical Panels shall be constructed of a composite
core construction of dimensionally stable rigid fiberglass
of medium density, laminated to a 1/16” resilient perforated
co-polymer face sheet. Thickness (choose one) 1-1/16”, 1-9/16”,
2-1/16” or custom __________ (specify).
2.3 Sizes: ______ width and _______ high or as shown on
drawings. Standard maximum size is 48” wide x 120”
high (nominal). Custom or larger sizes up to 53” widths
are available; consult manufacturer. Panels are to be
manufactured according to field dimensions supplied by the
installing contractor. Standard tolerances are ± 1/16” in width
and length.
2.4 Edge profile shall be: Square, full bevel, half-bevel, miter, or
custom __________________ (specify). Corner detail shall
be: Square, radius or custom _______________ (specify).
Edge treatment shall be: resin hardened, aluminum or highpressure laminate (with square edge only), wood (all profiles
available) or custom _______________ (specify).
2.5 Panel finish shall be ______________________________
__________ (specify finish manufacturer, pattern, color and
specifier). Finish shall be applied directly over the face and
edges of the panel and returned to the back of the panel to
provide a full finished edge. All corners are fully tailored.
2.6 Mounting shall be: Adhesive/Resin, Adhesive No Resin,
Impaling/Adhesive, Lay-in, Magnet, Spline, VELCRO®, Panel
Clip to Wall Bar, Panel Clip to Double Wall Clip, Z-Bar to
Z-Bar (recommended for ceilings), Aluminum Z-Clips, Panel
Clips/VELCRO® or custom ________________ (specify).
Adhesive, miscellaneous fasteners, (i.e. nails, screws, etc.) and
standard continuous wall leveling angle are to be supplied by
the contractor.
2.7 Acoustical Performance – panels shall have a minimum NRC
of _____ (please specify).
2.8 Flammability – All panel components shall have a Class “A”
fire rating in accordance with ASTM E-84.
2.9 R-Value is _____. (Calculated using the R-factor of 4.16 per
inch of thickness.)
Thank you for choosing Conwed D