Product Data Sheet
FOUNDATIONS WALL PANELS
PART 1 GENERAL
1.1
The extent of the acoustical panels is shown on the
drawings and in the schedules.
Edge profile shall be: Square, full bevel, half-bevel, miter, or
custom __________________ (specify). Corner detail
shall be: Square or custom _______________ (specify).
Edge treatment shall be: resin hardened, aluminum or
high-pressure laminate (with square edge only) or custom
_______________ (specify).
2.5
Panel finish shall be soft texture acoustically transparent
finish. Finish shall be applied directly over the face and
edges of the panel to provide a full finished edge. All
corners are fully tailored. Note: factory painting is
available and referred to as “Subtle Texture”.
2.6
Mounting shall be: Adhesive/Resin, Impaling/Adhesive,
Lay-in, Magnet, Spline, VELCRO,® Panel Clip to Z-Bar,
Panel Clip to Double Wall Clip, Z-Bar to Z-Bar,
Aluminum Z-Clips, Panel Clips/VELCRO® or custom
________________ (specify). Adhesive, miscellaneous
fasteners, (i.e. nails, screws, etc.) and standard continuous
wall leveling angle are to be supplied by the contractor.
2.7
Acoustical Performance – panels shall have a minimum
NRC of _____ (please specify).
2.8
Flammability – All panel components shall have a Class
“A” fire rating in accordance with ASTM E-84.
Work in this section shall be subject to drawings, general
conditions, schedules, addenda and other contract
documents.
1.2
2.4
1.3
Submit _______ (select quantity) samples of each type
of acoustical panel as shown on the drawings and in
schedules and include appropriate technical information
including test data and maintenance instructions. Submit
__________ (select quantity) fabric selector cards from
manufacturer’s standard finishes, or designer specified
finishes.
1.4
Acoustical panels shall be installed according to
manufacturer’s recommendations and instructions.
1.5
Installation of acoustical panels shall not begin until all wet
work (plastering, concrete, etc.) is completed and dry.
Building shall be properly enclosed and under standard
occupancy conditions (temperature of 60-85°F and not
more than 70% relative humidity) before installation
begins.
The contractor shall be responsible for the examination
and acceptance of all surfaces and conditions prior to the
acoustical panel installation.
1.6
1.7
Substitutions or changes will only be permitted by prior
approval by the architect.
PART 2 MATERIALS
2.1
Acoustical wall panels shall be: Foundations Wall Panels as
manufactured by Conwed Designscape|Wall Technology,
800 Gustafson Road, Ladysmith, WI 54848.
Phone (800) 932-2383, fax (800) 833-4798.
2.2
Sizes: ______ width and _______ high or as shown on
drawings. Standard maximum size is 48” wide x 120” high.
Custom or larger sizes available; consult manufacturer.
Panels are to be manufactured according to field
dimensions supplied by the installing contractor. Standard
tolerances are ± 1/16” in width and length.
The information provided above is correct to the best of our
knowledge at time of printing. We reserve the right to make
changes without prior notification.
DISCLAIMER OF LIABILITY
Technical information contained herein is furnished without charge or obligation and is
given and accepted at recipient’s sole risk. Because conditions of use may vary and are
beyond our control, Owens Corning makes no representation about, and is not responsible
or liable for the accuracy or reliability of data associated with particular uses of any product
described herein. Nothing contained in this bulletin shall be considered a recommendation.
Acoustical Panels shall be constructed of a composite
core construction of dimensionally stable rigid fiberglass
of 6-7 pcf density laminated to 1/8” 16-20 pcf molded glass
fiber. Thickness (choose one) 3/4”, 1”, 1-1/2”, 2”, 3”, 4” plus
1
/8” or custom ____________ (specify).
2.3
Thank you for choosing Conwed Designscape|Wall
Technology for your acoustical needs.
+YWXEJWSR 6SEH
0EH]WQMXL;MWGSRWMR
T: 1-800-932-2383
F: 1-800-833-4798
www.conweddesignscape.com
4YF2S%4VMRXIH MR 97%%TVMP
3[IRW 'SVRMRK%PP 6MKLXW 6IWIVZIH
0))( MW E VIKMWXIVIH XVEHIQEVO SJ 97+VIIR &YMPHMRK 'SYRGMP