Eurospan® Acoustical Wall System
PROJECT ARCHITECT RESPONSIBILITY: This is a general specification guide, intended to be used by experienced construction
professionals, in conjunction with good construction practice and professional judgment. This guide is to aid in the creation of a
complete building specification that is to be fully reviewed and edited by the architect of record (specifier). Sections of this guide
should be included, edited, or omitted based on the requirements of a specific project. It is the responsibility of both the specifier and
the purchaser to determine if a product or system is suitable for its intended use. Neither Owens Corning, nor any of its subsidiary or
affiliated companies, assume any responsibility for the content of this specification guide relative to actual projects and specifically
disclaim any and all liability for any errors or omissions in design, detail, structural capability, attachment details, shop drawings or
other construction related details, whether based upon the information provided by Owens Corning or otherwise.
SECTION 098414 – ACOUSTIC STRETCHED FABRIC WALL SYSTEMS
PART 1 - GENERAL
1.1
SUMMARY
A.
1.2
Section Includes: Acoustic stretched fabric wall system, consisting of a textile applied over a glass-fiber acoustic core
and attached to a continuous mounting system. (Eurospan Acoustical Wall System)
SUBMITTALS
A.
Product Data: Submit manufacturer’s product data including certified laboratory test reports and other data required to
show compliance with these specifications.
B.
Shop Drawings: Submit shop drawings showing typical wall elevations, sectional views and details of construction.
C.
Samples: Submit 12 by 12 inch samples of representative fabric with factory detailed edge, and representative samples
of mounting devices.
D.
Certified Test Reports: Submit test data from an independent testing agency, acceptable to authorities having
jurisdiction, evidencing that systems components comply with requirements indicated for fire performance and recycled
content characteristics. Submit test data from independent testing agencies showing that system complies with the
specified requirements for acoustical performance.
E.
Extra Stock: Submit an additional 2 percent of each fabric as extra stock for future use.
1.3
QUALITY ASSURANCE
A.
Recycled Content: Fiberglass board core eligible to bear the Green Cross label for recycled content, certified on
average to contain at least 30 percent recycled glass, with at least 4 percent post-consumer glass content.
B.
Installer Qualifications: Owens Corning Certified Installer.
1.4
DELIVERY, STORAGE, AND HANDLING
A.
1.5
Project Conditions: Protect system components from excessive moisture in shipment, storage, and handling. Deliver in
unopened bundles and store in a dry place with adequate air circulation. Do not deliver material to building until wet
conditions such as concrete, plaster, paint, and adhesives have been completed and cured to a condition of equilibrium.
LIMITED WARRANTY
A.
Limited Warranty: Provide manufacturer’s standard 5-year warranty against defects in materials and manufacturing.