Step 5
Secure the Wood Top in Place
(Two Wall Corner With Open End)
5.2
Use #7 x 1-1/4” screws along the front stretch-
ers of the cabinets into the Wood Top from below.
5.1
Before placing the scribed Wood Top in fi nal
position, install angle brackets at each end and every
four feet along the back of the cabinets.
Place a screw within 3” of any cabinet side or pair of
sides.
If it is shorter than four feet in length, the angle brackets
may be replaced with dollops of construction adhesive.
Place a screw through the angle brackets into the Wood
Top at the back of the cabinet if they are being used.
Finish Top Attachment
Angle Brackets
or Dollops of
Construction Adhesive*
Placed 3” From Each End
and No Further Than 4’ Apart
#7 x 1-1/8” Screws
Through Front Stretcher
Into Finished Top
(* only if tops are shorter than 4’ in length)
Special
Layout, Mark and Scribe Cut Wood Tops
(Three Wall Niche)
SP.1 Measure the
wall conditions with a
straight edge and a
carpenters square.
120
Finished Top Niche Layout
Out of Square Condition
Determine any “Out
of Square” conditions
in the side walls and
calculate the “Actual
Wood Top Size”.
Add 1/4” to the “Actual
Wood Top Size”. The
result will be the rough
cut size for the Wood
Top.
Actual
Finished Top Size
Out of Square Condition
©2017 PCS Professional Cabinet Solutions. All Rights Reserved.
Section 1: IMS 120
7