1.4 Determine
the width of Filler
2 by measuring
the distance from
Mark A made in the
previous step to
the original layout
position for Cabinet
2, drawn previously
on the wall during
layout.
1.5
Rip the
two fi ller halves to
width.
Confi rm that the
two pieces are the
exact length of the
cabinet boxes.
Even Spacing
16”
or Less
3”
3”
FIller 1
1.6 Predrill Filler 1 with 3/16” holes approximately three
inches from each end and evenly spaced between the end holes
(but not greater than 16” apart).
Secure the two halves with #7 x 1-5/8” fl athead screws.