Expert Solutions Industrial Process & Emissions Issue 20 | Page 14

PRODUCT FOCUS SERVICE FOCUS SIL 2 RATING FOR OxyExact 2200 TRANSMITTER UNIT (2222H) KEEP YOUR ZIRCONIA SENSOR AT PEAK PERFORMANCE The SERVOTOUGH OxyExact 2200 is a high-precision Paramagnetic oxygen analyzer designed for hazardous area installations in the process industry, configured with a control unit with up to six transmitters. The SERVOTOUGH FluegasExact 2700 is designed for reliable operation in some of the most hazardous and challenging conditions. It uses trusted, industry-proven Zirconia sensing for measuring oxygen in combustion processes, with an extractive sampling system to protect against harsh process environments. In addition to the existing 2223 transmitter versions, the high- temperature OxyExact transmitter unit (2222H) has now been assessed as being SIL 2 compliant for use in safety instrumented systems in respect of hardware integrity only, according to IEC 61508 part 2:2010. The assessment covers 2222Hs configured with or without the optional internal flow alarm feature. As a result, a new Functional Safety manual has been released (02220006A) that covers both transmitter versions of the OxyExact 2200. This manual provides information and instructions that will be needed in order to use both versions of the transmitter in safety instrumented systems. The 2222H transmitter is designed for use in process control applications where high- temperature, high-performance oxygen measurements are required. This includes the manufacture of ethylene oxide, propylene oxide, ethylene dichloride, and vinyl acetate monomer acid. P14 IMPROVEMENTS Field-proven Paramagnetic cell measurement technology. Sample compartment temperature up to 110 o C (230 o F). Sample gas pressure of up to 45psia. Measurement of enriched oxygen in potentially flammable sample gases. Certification for hazardous areas meeting ATEX, IECEx, FM & CSA compliance. Multiple transmitter operation in conjunction with an OxyExact control unit (two-wire digital connection for easy installation). However, to ensure the analyzer continues to operate at the highest levels of performance, and to provide peace of mind that measurements continue to be as accurate as possible, regular health checks are recommended. CHECKS Diagnostics, including sensor temperatures and signal voltages. Enclosure doors are closed and cable glands secure. Conducted on-site by an expert engineer from our global Service Network, a health check delivers complete assurance that the analyzer is performing within specification. Analyzer damage caused by heat, abrasion, misuse, etc. See the table for checks that might be carried out by an engineer for the Zirconia analyzer on a FluegasExact 2700. Checking mA and relay operation. Choosing a health check allows for a proactive approach to maintenance for your FluegasExact 2700, detecting any anomalies before they become costly problems, and avoiding downtime for unscheduled repairs. See all Service products at servomex.expert/service Making sure the aspirator air setting is correct. Testing the analyzer responds correctly to calibration gases. Examining probes and probe filters. Calibrating oxygen, COe and flow sensors. P15