Expert Solutions Chroma NanoChrome Issue 19 | Page 22

S E R V O P R O NanoChrome SUB-PPB TRACE MEASUREMENT OF H 2 , CH 4 , CO, CO 2 , N 2 , Ar AND NMHC FOR THE SEMICONDUCTOR INDUSTRY Incorporating the latest advances in gas sensing technology and signal processing methodology, the NanoChrome revolutionizes ultra-trace purity measurements for the semiconductor industry. FEATURES AND BENEFITS In compliance with Low Voltage, EMC and applicable Directives New PED Sensor technology enables sub-ppb measurements of H 2 , CH 4 , CO, CO 2 , N 2 , Ar and NMHC SAFE AREA MEASURES GAS APPLICATION ppb MULTIPLE ULTRA TRACE ppt ULTRA TRACE Enables unique total Servomex solution for UHP gas analysis QUALITY APPLICATIONS Semiconductor production – quality control measurements S E R V O P R O HFID SAFE AREA HIGH-PERFORMANCE FAST ANALYSIS USING HEATED FID FEATURES AND BENEFITS Using a highly sensitive heated Flame Ionization Detector (HFID) for measuring volatile hydrocarbon concentrations in industrial or vehicle emission applications, the HFID utilizes an internally heated oven set to 190 o C to maintain the sample gas above the dew point of most hydrocarbons expected to be present, for optimum performance in total hydrocarbon (THC) analysis. Can be equipped with a non-methane cutter for additional methane (CH 4 ) and non-methane hydrocarbon (NMHC) reporting. Four user-definable measurement ranges, reconfigurable in the field High-accuracy, gas-selective FID technology for maximized uptime Heated oven for maximum stability and "hot/wet" sampling EPA Method 25A compliant EPA 1065/1066 and LD Euro 6, HD Euro V1 compliant Heated FID detector at 190 o C for the most accurate THC determination APPLICATIONS Semiconductor production – stationary analytical systems Continuous emissions monitoring (CEM) SENSING TECHNOLOGY Scrubber efficiency Compliance monitoring and testing S E R V O P R O NOx SAFE AREA CHEMILUMINESCENCE DETECTOR (CLD) ANALYZER FOR KEY EMISSIONS APPLICATIONS INVOLVING ULTRA-LOW NO, NO 2 AND NOx FEATURES AND BENEFITS Utilizing Chemiluminescence detection technology to measure NO or NO/NO 2 /NOx concentrations in industrial gas and vehicle emission applications, the versatile SERVOPRO NOx can be calibrated for four measurement ranges starting from ultra-low to high ppm and is easy to install and operate. Heated version available for wet-to-dry conversion option High-dynamic-range NOx emissions monitoring solution with a fast response Non-depleting light-based measurement and electronic flow control keeps costs low Mobile Source emissions standard EPA 1065/1066 and LD Euro 6, HD Euro V1 compliant APPLICATIONS Continuous emissions monitoring (CEMS) MEASURES GAS APPLICATION ppm NO TRACE NITRIC OXIDE PROCESS CONTROL NO 2 NITROGEN DIOXIDE FEATURES AND BENEFITS Life safety monitor designed for safe area or hazardous area environments, utilizing superior performance of award-winning, non-depleting Hummingbird Paramagnetic O 2 sensing technology. TOTAL HYDROCARBONS PROCESS CONTROL CH 4 METHANE EMISSIONS NMHC NON-METHANE HYDROCARBONS QUALITY SENSING TECHNOLOGY FLAME IONIZATION DETECTOR IP66 (indoor use only) The most reliable O 2 detector on the market No more false readings or false alarms caused by depleting cell technologies SERVOMEX MEASURES GAS APPLICATION % O 2 PERCENT SAFETY OXYGEN SIL 2 compliant APPLICATIONS EMISSIONS Pharmaceutical plants NOx Helium production and storage NITROGEN OXIDES Semiconductor facilities QUALITY Laboratories and universities SENSING TECHNOLOGY Scrubber efficiency TRACE G A S D E T E C T I O N OxyDetect NON-DEPLETING PARAMAGNETIC O 2 MONITOR DESIGNED FOR LIFE SAFETY APPLICATIONS APPLICATION ppm THC VOC abatement UHP gas production – quality control measurements MEASURES GAS SENSING TECHNOLOGY Turbine/generator feedback control SCR/SNCR feedback control CHEMILUMINESCENCE S E R V O P R O SO 2 USES PROVEN PULSED UV FLUORESCENCE TECHNOLOGY TO DELIVER A PRECISE AND RELIABLE MEASUREMENT OF ULTRA-LOW SULFUR DIOXIDE IN EMISSIONS AND AMBIENT AIR For industrial applications that require ultra-low emissions monitoring of sulfur dioxide, this robust analyzer is designed to slot seamlessly into rack systems, making it easy to integrate with existing emissions monitoring systems to provide unrivaled performance. SAFE AREA FEATURES AND BENEFITS MEASURES GAS ppm Ultra-long-lasting UV light source Removable flash memory stores up to 10 years of data Operation over wide temperature range reduces cost of ownership APPLICATION SO 2 TRACE ppb SULFUR DIOXIDE PROCESS CONTROL ULTRA TRACE User selectable dual ranges with auto-ranging Easy maintenance procedures EMISSIONS INTRINSICALLY SAFE ANALYZER MEASURES O 2 , CO OR CO 2 FEATURES AND BENEFITS Designed for the measurement of toxic and flammable gas samples, the intrinsically safe Micro i.s. 5100 is a unique analyzer certified to Zone 0 and Zone 1 and suitable for measuring percent levels of O 2 , CO and CO 2 . Intrinsically safe design to ATEX and IEC standards ensures safety operation in hazardous environments Ergonomic design ensures easy operation on the move Available in non-pump or pump versions with optional sample conditioning kit APPLICATIONS Hazardous area combustion optimization APPLICATIONS Refineries – catalytic cracker regeneration Continuous emissions monitoring (CEMS) Ambient air monitoring S E R V O F L E X Micro i.s. 5100 QUALITY SENSING TECHNOLOGY Process monitoring Inerting applications PORTABLES GAS MEASURES O 2 % APPLICATION PERCENT OXYGEN COMBUSTION CO CARBON MONOXIDE PROCESS CONTROL CO 2 CARBON DIOXIDE SAFETY SENSING TECHNOLOGY UV FLUORESCENCE P22 WE CAN BUILD YOUR ANALYZER INTO A COMPLETE GAS ANALYSIS SYSTEM Visit servomex.expert/systems or contact your local business center today P23