Eversight Services Information 2017 | Page 8

EVERSIGHT SERVICES DMEK: DESCEMET MEMBRANE ENDOTHELIAL KERATOPLASTY DMEK PREPARED TISSUE Epithelium Endothelium Stromal bed Epithelium 2mm Punch/Micro Stromal Stamp Combination After creation of either the peripheral or central hinge, a 2mm trephine is used to punch through the remainder of the stromal bed. The 2mm punch plug is removed and the Descemet's is returned to the stromal bed. The stamp is then applied to the stromal side of Descemet's through the 2mm hole from the epithelium side of the tissue. The 2mm punch plug is replaced during transport. Endothelium Fold-Over Micro Stromal Stamp After creation of the peripheral hinge, the edge of the Descemet's is left on a dry area of the scleral rim, and the stamp is applied directly to the stromal side of Descemet's. The Descemet's is then returned to the stromal bed. Single Partial Trephination Options Standard: 9.5mm Other options: 8.0, 8.5 and 9.0mm Double Partial Trephination Options Standard 9.5mm single partial trephination 7.25, 7.5, 7.75 or 8mm double partial trephination 1mm Trephination Series (View from endothelium) After creation of either the peripheral or central hinge, the Descemet's is returned to the stromal bed. A 1mm trephine is then used to punch through the Descemet's at the periphery of the partially trephinated button. When viewed from the endothelium side, the 1mm trephine series will be seen as half-circles at 12, 1 and 4 o'clock. Corneas and markings are to scale and shown at approximately 300%. Questions? Contact: Lauren Johnson • [email protected] • (800) 247-7250 ext. 2597