Breaches, prosecutions and infringements Winter 2020 energysafe issue 58 Identified non-compliance breaches By Paul Harris, Head of Gas Operations Rating Cause Clause description 1 AS/NZS 5601.1:2013 Breaches Clause 6.2.2 2 AS/NZS 5601.1:2013 Breaches GENERAL INSTALLATION REQUIREMENTS – Manufacturer’s installation instructions 18 Non-compliances » Appliances have not been installed in accordance with the requirements of Australian Standard AS/NZS 5601.1:2013 and the manufacturer’s instructions. » Cook tops: » not secured in position » not installed as per instructions » anti-tilt bracket not installed » combi-oven minimum clearance required 500mm » appliance distance to wall was not 50mm. » Range hood: » installed below the manufacturer’s requirements. » Heaters (space/radiant): » installed too close to a cupboard » manufacturer’s components not installed, no vermin plate, no metal support bracket, no internal support plate fitted to maintain gradient to external wall » installed radiant heaters exposed to rain. » Boiler flues not installed on grade to drain back to appliance. » Wafer type valve only has four studs installed. » TPR valve has reduced drain pipe size. » Hot water: » condensation pipe on unit flue not fit for purpose » condensate pipe drained into galvanised steel tray » protective mesh built close to hot water front cover, manufacturer clearance required for maintenance » condensate drains are connected to copper sewer drain, which is an unsuitable point of discharge. » Barbeques: » not installed to instructions regarding clearances to combustibles. Clause 5.3.8 LOCATION OF CONSUMER PIPING – Piping in a concealed location other than underground or embedded in concrete 17 Non-compliances » Consumer piping in a concealed location is not installed in accordance with AS/NZS 5601.1, Table 5.2, and Clause 5.3.12 (ventilation requirements). » Mechanical joints are within a concealed location (like a pipe shaft/cupboard). » An isolation valve with mechanical joints is in a wall. » Piping or a riser shaft in cupboard is not sealed from the ceiling to prevent potential gas escapes into adjacent ceiling spaces. » Mechanical joints are in an unventilated area. » Identifying signage is required. » Concealed pipework to a cook top requires ventilation. » Floor isolation valves have not been installed in a constructed box and should not be in the ceiling space. 3 AS/NZS 5601.1:2013 USE OF HOSE ASSEMBLIES – Hose assembly – Operating conditions Breaches Clause 5.9.5 10 Non-compliances » Hoses and connections behind commercial appliances are subject to strain, kinking, and distortion. » Buffers have not been fitted to prevent hose kinking. » Hose on range passes around shelves and is subject to damage. » Appliances connected with a hose assembly are not installed in ‘U’ shape. » Appliance hoses kink when the appliance is pushed back into position. 20