esv.vic.gov.au Defect code 111002 relates to the Electricity Safety Act 1998 section 44 Compliance and testing of electrical installation work subsection 3, which states: 3. A  licensed electrical installation worker must not sign a certificate of compliance in relation to any electrical installation work carried out by that worker unless the certificate – (a) describes the work; and (b) states that the work complies with this Act and the regulations; and  any other details in (c) contains relation to the work required by the regulations. Defect code 111003 relates to the Electricity Safety Act 1998 section 45A Certificates of electrical safety, subsection 2. Where the Certificate of Compliance for Non-Prescribed Electrical Installation Work has been issued where all or part of the work is deemed to be Prescribed Electrical Installation Work. Defect code 211146 relates to AS/NZS 3000: 2007 (+A1, +A2) Wiring Rules clause 2.9.5.4 Terminals of switchboard equipment. Terminals of bars, links, circuit-breakers, fuses and other electrical equipment mounted on a switchboard shall be marked or arranged to identify the corresponding active and neutral connection for each circuit. New facility, new location • New purpose built Licenced Electrician’s Assessment (LEA) venue 20km from CBD • Easy access via major arterials • Car parking on-site • Comfortable environment • Café on site • Industry directed facility Defect code 211175 relates to AS/NZS 3000: 2007 (+A1, +A2) Wiring Rules clause 3.10.3.6 Terminations. Terminations shall be arranged so that wiring enclosures terminate in, and are supported on, electrical equipment in such a manner as to fully protect the enclosed cables as they pass into the electrical equipment. Each end of flexible conduit shall be securely anchored to the fixed conduit, structure or electrical equipment where it terminates. Defect code 211025 relates to AS/NZS 3000: 2007 (+A1, +A2) Wiring Rules clause 1.7.2 Installation work practice. In order to address the essential requirement of Clause 1.7.1, electrical equipment shall be installed in accordance with safe and sound work practices. Doncaster Eastern Freeway Melbourne CBD Nunawading Box Hill Richmond Camberwell Burwood Prahran Eastlink Chadstone Mount Waverley Glen Waverley Caulfield Monash Freeway Oakleigh Bentleigh East Wellington Road Monash University Future Energy Skills Mulgrave Moorabbin Springvale 8A, Level 3, Building 2 195 Wellington Road, Clayton T 03 9654 1299 E [email protected] 07