Emitter Electronics 9
IO Node-Controller
MMX IO node provide a smart solution for defining operation of different kind of vehicle consumers. Sensors, switches, CAN messages and other inputs can be easily connected.
Besides, other MMX modules data as keyboards, a pump governor, etc. can take part in defining outputs operation. Several IO nodes can be connected over Emitter CAN to collaborate.
IO nodes-controllers needs to be configured with Emitter Electronics MMX PC configuration tool. A Standard IO Node has two 12 pin connectors. Almost all pins are configurable. Black Connector is dedicated to power supply and CAN support as well as, among others, to analogue inputs. On the other hand, Grey connector offers 12 pins for digital inputs or outputs.
Grey connector: Pin Description
Pin |
Type |
|
Options |
|
|
1 |
Configurable |
Digital Input +/- |
Digital Output +/- |
PWM |
|
2 |
Configurable |
Digital Input +/- |
Digital Output +/- |
PWM |
|
3 |
Configurable |
Digital Input +/- |
Digital Output +/- |
PWM |
RS485, Relay, etc( via UART) |
4 |
Configurable |
Digital Input +/- |
Digital Output +/- |
PWM |
RS485, Relay, etc( via UART) |
5 |
Configurable |
Digital Input +/- |
Digital Output +/- |
PWM |
relay, etc( via SPI) |
6 |
Configurable |
Digital Input +/- |
Digital Output +/- |
PWM |
relay, etc( via SPI) |
7 |
Configurable |
Digital Input +/- |
Digital Output +/- |
PWM |
DAC, Relay, etc( via I2C) |
8 |
Configurable |
Digital Input +/- |
Digital Output +/- |
PWM |
DAC, Relay, etc( via I2C) |
9 |
Configurable |
Digital Input +/- |
Digital Output + |
|
|
10 |
Configurable |
Digital Input +/- |
Digital Output + |
|
|
11 |
Configurable |
Digital Input +/- |
Digital Output + |
|
|
12 |
Configurable |
Digital Input +/- |
Digital Output + |
|
|
• Output current of each output pin is limited to 1 A.
• Acquisition of 4 analogue values is supported with several signal ranges: 4 – 20 mA, 0 – 5 V, 0 – 10 V.
• Sealed and compact enclosure with industry standard Deutsch connectors.
• Integrated dual CAN, one of them with SAE J1939 support.
• Highly configurable via software tool with diagnostic and simulation support.
• Incremental output shedding capability.
• Supply voltage 8 – 30 V DC.
• Industrial temperature range-40 to + 85 ° C( 105 ° C).