Emitter Electronics 13
mmx pg
Cavitation warning / cycle RPM and pressure mode RPM indicator Three user-defined keys Illuminated
MMX Pump Governor
The Pressure Governor allows automated regulation of the engine RPMs according to the pressure fluctuations in the pump, which ensures a constant water flow at the nozzle regardless of the number of connected users.
The automatic pressure regulation is turned ON by turning the rotation switch- encoder. This will cause the pressure to increase to 4 bars. The pressure can subsequently be adjusted to the desired value using the encoder in 1 bar increments. If the manual keys for manual control of the RPMs( pressure) are used while the automatic regulation is running, the automatic regulation will be turned off. The pressure can then be increased and decreased manually or set to automatic again by turning the encoder.