Load Monitoring - Load Cells
Ron 4000 Load Cell with built-in Amplifier
Ron 4000C 4-20mA Output | Ron 4000V 0-2V Output | Ron 4000VC 0-2V + 4-20mA Outputs
TECHNICAL SPECIFICATIONS
Safety Factor: 5:1.
Proof Load: Each system proof-loaded to 200% of capacity (certified)
up to a test force of 400t.
Load Cell Material: High-strength, aerospace quality alloy steel,
polyurethane coated.
Linearity: 0.1% f.s
Input: 9 to 48 vdc
Output: 0 to 2v. Options: 4 to 20mA, 0 to 2v + 4 to 20mA.
Cable: supplied with 9' (3m) cable.
Temperature Range: -15°f to +175°f (-25°c to +80°c).
Environmental: Weatherproof, NEMA 4, IP 65.
32
Calibration: Supplied with approximate calibration (final calibration
is performed by the customer, after connecting the load cell to the
measuring / control system).
Zero load = 0+0.05v, 4±0.2mA. Full load = 2-0.1v, 20-1mA.
Max. Input Current: 100mA.
Input Voltage: 12-36 VDC.
Wiring:
Input voltage Red
Common Black
Output V White
Output A Green
Body without insulation