Eilon Engineering Industrial Product Catalog | Page 32

Load Monitoring - Load Cells Ron 4000 Load Cell with built-in Amplifier Ron 4000C 4-20mA Output | Ron 4000V 0-2V Output | Ron 4000VC 0-2V + 4-20mA Outputs TECHNICAL SPECIFICATIONS Safety Factor: 5:1. Proof Load: Each system proof-loaded to 200% of capacity (certified) up to a test force of 400t. Load Cell Material: High-strength, aerospace quality alloy steel, polyurethane coated. Linearity: 0.1% f.s Input: 9 to 48 vdc Output: 0 to 2v. Options: 4 to 20mA, 0 to 2v + 4 to 20mA. Cable: supplied with 9' (3m) cable. Temperature Range: -15°f to +175°f (-25°c to +80°c). Environmental: Weatherproof, NEMA 4, IP 65. 32 Calibration: Supplied with approximate calibration (final calibration is performed by the customer, after connecting the load cell to the measuring / control system). Zero load = 0+0.05v, 4±0.2mA. Full load = 2-0.1v, 20-1mA. Max. Input Current: 100mA. Input Voltage: 12-36 VDC. Wiring: Input voltage Red Common Black Output V White Output A Green Body without insulation