Overload Detection
Ron 1000 Hook Type Overload Detector
TECHNICAL SPECIFICATIONS
Safety Factor: 5:1. Each system proof-loaded to 200% of capacity (certified). Temperature Range: -4°F to +175°F (-20°C to + 80°C).
Switching Nature: Normally open and normally closed. Cable Length: 9.5' (3m).
Rating: 0.5A @ 50 VDC, 0.5A @ 125 VAC. Material: High strength steel.
Life Expectancy: Electrical: over 1 million operations. Mechanical: over 5
million operations. Wiring:
Environment: Weatherproof, NEMA 4, IP 65.
Overload Detection Point: Default: 100% to 110% of capacity.
Cat no.
Capacity
tons
G Max
H Max
mm. inch mm. inch
Cat no.
Capacity
tons
G Max
H Max
mm. inch mm. inch
H-002 0.25 7 5 /
16 19 3/4 H-015 1.5 9 3 /
8 21 13/16
H-005 0.5 7 5 /
16 19 3/4 H-016 1.6 9 3 /
8 21 13/16
H-007 0.75 7 5 /
16 19 3/4 H-02 2.0 11 7 /
16 23 7/8
H-008 0.8 7 5 /
16 19 3/4 H-025 2.5 13 9 /
16 25 1
H-01 1.0 7 5 /
16 19 3/4 H-03 3.0 15 5 /
8 27 1 1/16
H-012 1.25 7 5 /
16 19 3/4 H-032 3.2 15 5 /
8 27 1 1/16
OPTIONS
› Additional detection point.
› The company reserves the right to make changes without notice.
www.EilonEngineering.com
31