Eilon Engineering Industrial Product Catalog | Page 31

Overload Detection Ron 1000 Hook Type Overload Detector TECHNICAL SPECIFICATIONS Safety Factor: 5:1. Each system proof-loaded to 200% of capacity (certified). Temperature Range: -4°F to +175°F (-20°C to + 80°C). Switching Nature: Normally open and normally closed. Cable Length: 9.5' (3m). Rating: 0.5A @ 50 VDC, 0.5A @ 125 VAC. Material: High strength steel. Life Expectancy: Electrical: over 1 million operations. Mechanical: over 5 million operations. Wiring: Environment: Weatherproof, NEMA 4, IP 65. Overload Detection Point: Default: 100% to 110% of capacity. Cat no. Capacity tons G Max H Max mm. inch mm. inch Cat no. Capacity tons G Max H Max mm. inch mm. inch H-002 0.25 7 5 / 16 19 3/4 H-015 1.5 9 3 / 8 21 13/16 H-005 0.5 7 5 / 16 19 3/4 H-016 1.6 9 3 / 8 21 13/16 H-007 0.75 7 5 / 16 19 3/4 H-02 2.0 11 7 / 16 23 7/8 H-008 0.8 7 5 / 16 19 3/4 H-025 2.5 13 9 / 16 25 1 H-01 1.0 7 5 / 16 19 3/4 H-03 3.0 15 5 / 8 27 1 1/16 H-012 1.25 7 5 / 16 19 3/4 H-032 3.2 15 5 / 8 27 1 1/16 OPTIONS › Additional detection point. › The company reserves the right to make changes without notice. www.EilonEngineering.com 31