Load Monitoring - Dynamometers Ron 2150 Shackle Type Dynamometer with 2"/50mm Attachable Display TECHNICAL SPECIFICATIONS Safety Factor: 5:1. Proof Load: Each system proof-loaded to 200% of capacity (certified) up to a test force of 400t. Accuracy: ± 0.1% of full range. Durability: Robust indicator with extruded aluminum housing, polyurethane coated. Load Cell Material: Made of high-strength, aerospace quality, alloy steel, polyurethane coated. Display: 5/6 digits, 2" (50mm) liquid crystal display with two overload warning levels, max. value (peak hold), low battery, tare state (gross or net), measuring unit, sleep state, programming instructions. Standard number of measurements per second: 1. Standard display update rate per second: 1. Sampling Rate: 200 per second. Functio