e-Showcase Huawei Smart PV Plant Solutions | Page 6

String Inverter (8-23KTL) Technical Specifications SUN2000-8KTL SUN2000-12KTL SUN2000-17KTL SUN2000-20KTL SUN2000-23KTL Efficiency Max. efficiency 98.5% 98.5% 98.6% 98.6% 98.6% European efficiency 98.0% 98.0% 98.3% 98.3% 98.3% Input Max. DC input 9,100 W 13,700 W 19,200 W 22,500 W 23,600 W Max. input voltage 1000 V 1000 V 1000 V 1000 V 1000 V Max. input current per MPPT 18 A 18 A 18 A 18 A 18 A Max. short circuit current per MPPT 25 A 25 A 25 A 25 A 25 A Operating voltage range 200 V - 950 V 200 V - 950 V 200 V - 950 V 200 V - 950 V 200 V - 950 V MPP voltage range at full loading 320 V - 800 V 380 V - 800 V 400 V - 800 V 480 V - 800 V 480 V - 800 V Rated input voltage 620 V 620 V 620 V 620 V 620 V Max. number of inputs 4 4 6 6 6 Number of MPP trackers 2 2 3 3 3 Output Rated output power 8,000 W 12,000 W 17,000 W 20,000 W 23,000 W Max. apparent output power 8,800 VA 13,200 VA 18,700 VA 22,000 VA 23,000 VA Rated output voltage 3×230V/400V+N+PE 3×220V/380V+N+PE 3×230V/400V+N+PE 3×220V/380V+N+PE 3×230V/400V+N+PE 3×220V/380V+N+PE 3×230V/400V+N+PE 3×220V/380V+N+PE 3×230V/400V+N+PE 3×220V/380V+N+PE AC power frequency 50 Hz/60 Hz 50 Hz/60 Hz 50 Hz/60 Hz 50 Hz/60 Hz 50 Hz/60 Hz Max. output current 12.8 A 19.2 A 27.2 A 32 A 33.5 A Adjustable power factor 0.8 leading ... 0.8 lagging 0.8 leading ... 0.8 lagging 0.8 leading ... 0.8 lagging 0.8 leading ... 0.8 lagging 0.8 leading ... 0.8 lagging Max. total harmonic distortion <3% <3% <3% <3% <3% Yes Yes Yes Yes Yes Type Ⅱ Type Ⅱ Yes Yes Yes Yes Yes Yes Yes Type Ⅱ Type Ⅱ Yes Yes Yes Yes Yes Yes Yes Type Ⅱ Type Ⅱ Yes Yes Graphic LCD Yes Yes Graphic LCD Yes Yes Graphic LCD Yes Yes Protection Input-side disconnection protection Anti-Islanding protection AC over current protection DC reverse-polarity protection PV array string fault monitoring DC surge arresters AC surge arresters Insulation monitoring Residual current detection Yes Yes Yes Yes Yes Type Ⅱ Type Ⅱ Yes Yes Yes Yes Yes Yes Yes Type Ⅱ Type Ⅱ Yes Yes Display RS485 USB Graphic LCD Yes Yes Graphic LCD Yes Yes Dimensions(W/H/D) 520 x 610 x 255 mm (20.5 x 24.0 x 10.0 in.) 520 x 610 x 255 mm (20.5 x 24.0 x 10.0 in.) 520 x 610 x 255 mm (20.5 x 24.0 x 10.0 in.) 520 x 610 x 255 mm (20.5 x 24.0 x 10.0 in.) 520 x 610 x 255 mm (20.5 x 24.0 x 10.0 in.) Weight 40 kg 40 kg 48 kg 48 kg 48 kg Operating temperature range -25 °C to +60 °C (-13 °F to +140 °F) -25 °C to +60 °C (-13 °F to +140 °F) -25 °C to +60 °C (-13 °F to +140 °F) -25 °C to +60 °C (-13 °F to +140 °F) -25 °C to +60 °C (-13 °F to +140 °F) Cooling Natural convection Natural convection Natural convection Natural convection Natural convection Operating altitude 3000 m 3000 m 3000 m 3000 m 3000 m Relative humidity (non-condensing) 0 - 100% 0 - 100% 0 - 100% 0 - 100% 0 - 100% DC connector Amphenol H4 Amphenol H4 Amphenol H4 Amphenol H4 Amphenol H4 AC connector Amphenol C16/3 Amphenol C16/3 Amphenol C16/3 Amphenol C16/3 Amphenol C16/3 Degree of protection IP65 IP65 IP65 IP65 IP65 Self-consumption at night <1W <1W <1W <1W <1W Topology Transformerless Transformerless Transformerless Transformerless Transformerless Noise emission ≤ 29 dB ≤ 29 dB ≤ 29 dB ≤ 29 dB ≤ 29 dB Warranty 5 years 10/15/20/25 years optional 5 years 10/15/20/25 years optional 5 years 10/15/20/25 years optional 5 years 10/15/20/25 years optional 5 years 10/15/20/25 years optional Safety/EMC EN61000-6-2,EN61000-6-3,EN61000-3-2,EN61000-3-3,EN61000-3-11,EN61000-3-12,EN/IEC62109-1,EN/IEC62109-2 Grid Code VDE-AR-N4105,VDE0126-1-1,BDEW 2008,Enel-Guideline,CEI 0-21,G59/3,G83/2,AS4777,CGC/GF004:2011,IEC61727,IEC62116,RD1669,UTE C 15-712-1 Display and Communication General Data Standards Compliance Always Available for Highest Yields [email protected] [email protected] Tel: 49 911 255 22 3053 Tel: 800 0889977