Central Inverter (500KTL)逆变器
SUN8000-500KTL
Higher Yields
Maximum efficiency 98.7%, European efficiency 98.5%
Dynamic system efficiency optimization with intelligent dormancy technology
Additional harvesting with 20% overload capacity
5~10% saving of medium voltage transformer investment with two-winding transformer
instead of double-split transformer
High Reliability
No interruption at single point failure with modular power stack design
Grid and self-generating switchable design, 1+1 redundancy of system power supply
Redundancy design of key circuits including grid voltage and current sampling to improve
accuracy and reliability
Smart
Comprehensive local management of system configuration and maintenance with LCD
touch screen
0~100% active power continuously adjustable and reactive power compensation for grid
management
RS485 and USB ports for data transferring and firmware update (Security protection
mechanism support)
Friendly