O Other
P2.2. Commercial Loading Area Separated for Residential Area( 1 Point)
The project should demonstrate that residential and commercial access is separated to avoid impacting the other uses. This should include the following:
Parking and loading for residential uses should be obviously separated from delivery parking and loading. Mechanical systems, entrances, hours of operation, and lighting must be designed to reduce impact on tenants in noise, vibration, odor, etc. Separation of waste and recycling facilities and waste pickup on site between residential and commercial uses. If a single waste and recycling center is provided, it should be in the commercial area of the project in order to screen the noise and smell of waste collection activities from residents.
P2.3. Separate Mechanical and Plumbing Systems( 1 Point)
The project should show that careful thought has been given to appropriate segregation of commercial and residential utilities. The appropriate level of utility segregation is left to the discretion of the mechanical designer, including the following:
� Improved insulation between uses in demising walls. � Separate residential and commercial metering for all utilities. � Proper separation of commercial and residential drain, waste, HVAC, and vent systems.. For instance, residential drains should not be subject to flow through any possible obstructions from commercial uses, such as sand traps, grease traps, etc. Food service and toilet fan exhausts from commercial uses should be separated from residential exhausts and entail deliberate noise and odor reducing practices.
VERIFICATION Measure P2.1 Documentation: The Rater shall review the GTG for compliance with all criteria. Measure P2.2
Field Verification: The Rater shall perform field verification to verify that design detail criteria have been satisfied.
Documentation: The Rater shall review plans and specifications. The Rater shall collect Accountability Forms from the MEP designer( s) confirming that the design detail criteria have been satisfied.
Measure P2.3

DRAFT

Field Verification: The Rater shall perform field verification to verify that design detail criteria have been satisfied.
Documentation: The Rater shall review plans and specifications. The Rater shall collect Accountability Forms from the MEP designer( s) confirming that the design detail criteria have been satisfied.
INTENT To promote compatible, mixed-use developments to use land efficiently and encourage civic engagement.
DRAFT GreenPoint Rated New Home Rating Manual Version 6.0, September 2013 115 © Build It Green