Dobbins JLUS IMP Public Draft Light Pollution Study | Page 294

Pattern Outdoor Lighting Code Standard ver. 2.0 any part of the fixture is lower than the upper edge of a window or door must be fully shielded (See Figure 4.10). Pattern Outdoor Lighting Code Standard ver. 2.0 A. Outdoor internally illuminated signs must either be constructed with an opaque background and translucent text and symbols, or with a colored background and generally LIGHTER text and symbols (Figure 5.2.A). Lamps used for internal illumination of internally illuminated signs shall not be counted toward the total outdoor light output limits in Section 4.2. Light Background : Colored Background Opaque Background ; ; Figure 4.10. Elevation cross-section view showing required shielding for indoor non-residential lighting (FS = fully shielded; A = allowed, fully shielded, partially shielded or unshielded) 4.11. Time Limits. A. Class 3 lighting shall be extinguished between 10:00pm (or when the business closes, whichever is later) and the time the business re-opens. B. Class 2 lighting located 75 feet or more from the nearest building, display area or storage area shall be extinguished between 10:00pm (or within 30 minutes of the business closing, whichever is later) and the time the business re-opens. Section 5. Outdoor Advertising Sign Lighting Standards. 5.1 Externally Illuminated Sign Lighting Standards. External illumination for signs, including billboards, shall conform to the provisions of this Code. Such lighting shall be treated as Class 1 lighting and shall conform to the lamp source, shielding restrictions and total outdoor light output limits of Section 4 (except as provided in Section A below). All upward-directed sign lighting is prohibited. Figure 5.2.A. Internally illuminated sign styles B. Neon signs, multicolor fixed-copy LED Signs and single-color LED signs (Figure 5.2.B) shall be treated as internally illuminated signs for the purposes of this Code, and shall not have their outputs counted toward the total outdoor light output limits in Section 4.2. Any lighting extending beyond the area considered to be the sign area (as defined in the Sign Code of this jurisdiction) shall conform to all provisions of this Code. In particular, such lighting shall be treated as Class 3 lighting (decorative) and shall conform to the total outdoor light output limits of Section 4. Neon Multicolor Fixed- Copy LED Single-Color LED A. Lighting for externally illuminated billboards may use up to 200 initial lamp lumens per square foot of sign face. Lighting for billboards is not included toward the total outdoor light output limits of Section 4.2. 5.2 Internally Illuminated Sign, Neon Sign, Multicolor Fixed-Copy LED Sign and Single-Color LED Sign Lighting Standards. Page C-6 11 Figure 5.2.B. Neon, multicolor fixed-copy LED and single-color LED signs C. Other internally-illuminated panels or decorations not considered to be signage according to the sign code of this jurisdiction (such as illuminated Appendix C: Pattern Outdoor Lighting Guide 12